Temperature and pressure

Clear explanations of concepts, methods, standards and measurements for engineers and technicians.

  • What is a dry-block calibrator?

    A dry-block calibrator is a temperature-controlled metal block with holes, heated or cooled, into which sensors are inserted to calibrate or verify them without the need for liquids; it is practical and portable.

  • What is a fluid calibration bath?

    A fluid calibration bath is a tank of stirred, temperature-controlled liquid in which sensors are immersed so that all of them are at the same temperature while they are compared with a reference thermometer.

  • What is a thermistor and when is it used?

    A thermistor is a resistor made of semiconductor material whose resistance changes greatly with temperature; it is used when high sensitivity is needed over a relatively narrow range, as in the thermal control of electronics and batteries.

  • What is hysteresis in a pressure sensor?

    Hysteresis in a pressure sensor is the difference between the output obtained for the same pressure depending on whether it is reached going up or going down; it indicates that the sensor “remembers” where it came from.

  • What is the dew point?

    The dew point is the temperature at which, when a gas is cooled at constant pressure, the water vapor it contains begins to condense; it measures how much moisture there is in absolute terms, independently of the gas temperature.

  • What is the international temperature scale?

    The international temperature scale is a practical scale, defined by agreement, that assigns temperature values to reproducible fixed points and specifies how to interpolate between them with defined instruments, in order to approximate thermodynamic temperature.

  • What is the Seebeck effect?

    The Seebeck effect is the appearance of a voltage in a circuit of two dissimilar conducting materials when there is a temperature difference between their junctions; it is the physical principle of the thermocouple.

  • What is the time constant of a temperature sensor?

    The time constant of a temperature sensor is the time it takes to cover about two thirds of a sudden temperature change; it indicates how quickly the sensor follows the medium, not how long it takes to stabilize completely.

  • What is vacuum pressure?

    Vacuum pressure is any pressure below atmospheric; it is better described as low absolute pressure than as “negative” pressure, and each vacuum level demands different sensors and precautions.

  • What range and span mean for an instrument

    The range is the minimum and maximum values the instrument is calibrated to measure; the span is the difference between the maximum and the minimum. Together they define how accuracy and adjustments are expressed.

  • What self-heating means in an RTD

    Self-heating is the rise in temperature of the sensing element caused by the measuring current passing through it, which dissipates power in the element. It introduces an error that depends on the medium and the current.

  • What test pressure is compared with operating pressure

    Operating pressure is what the equipment withstands in normal service; test pressure is higher and is applied in a controlled way to demonstrate strength and tightness. They are not interchangeable.

  • What the IEC 60584 thermocouple standard covers

    For letter-designated thermocouples (K, J, T, E, N, R, S, B), IEC 60584 sets out the electromotive force versus temperature functions and tables, along with the tolerance classes.

  • What the IEC 60751 standard specifies for platinum sensors

    The IEC 60751 standard covers industrial platinum resistance thermometers: it defines the resistance-temperature relationship, the tolerance classes and the general requirements for the sensor.

  • What the ITS-90 scale defines and why it matters in thermometry

    The International Temperature Scale of 1990 is the practical definition used to realize temperature in metrology: reproducible fixed points and interpolating instruments between them.

  • What the triple point of water means

    The triple point of water is the unique condition of temperature and pressure at which liquid water, ice and vapor coexist in equilibrium. Its temperature is a fixed reference point in thermometry.

  • What zero and full-scale readings are

    The zero reading is what the instrument indicates when the quantity is nil or equal to the lower limit of the range; the full-scale reading is what it indicates at the upper limit. Together they define the instrument's basic adjustment.

  • Why a leak test gives inconsistent results

    A leak test is inconsistent almost always because what changes is not the leak, but the temperature, the volume or the equilibrium of the system. A real loss has to be separated from a thermal or instrumentation effect.

  • Why a pressure transmitter shows a zero shift

    A transmitter's zero shifts because of sensor drift, mounting position, temperature, previous overpressure or a blocked atmospheric reference. External causes are ruled out first, and only then is it adjusted.

  • Why a thermocouple loses accuracy over time

    A thermocouple drifts because its wire changes: the composition and structure of the alloys are altered by temperature, atmosphere and thermal cycling, and the voltage it generates no longer follows the table.

  • Why an RTD shows error from its lead wires

    The wires connecting the RTD to the meter have their own resistance, and the meter adds it to that of the sensor. With two wires that sum is an error; with three or four wires it is compensated or eliminated.

  • Why overpressure damages a pressure sensor

    A pressure sensor is damaged when the fluid deforms it beyond its elastic limit: the diaphragm stretches permanently or fractures, and the zero or the sensitivity is left altered.