RF analyzers, generators and amplifiers
Tektronix RTSA306B spectrum analyzer rental
The RSA306B is a compact USB spectrum and signal analyzer with professional performance. It incorporates advanced functions normally found in instruments up to twice its size and cost. It is suited to both laboratory and field work.
83006A RF and microwave amplifier
The Keysight 83006A microwave system amplifier (formerly Agilent or HP) is an ultra-compact broadband unit. It recovers signal losses and increases the power available in automated test equipment (ATE) systems and design benches. It provides continuous coverage from 10 MHz to 26.5 GHz, so a single unit replaces several narrowband amplifiers.
E4406A vector signal analyzer
We rent the Agilent / Keysight E4406A, a vector signal analyzer (VSA) with various options. It is a high-performance analysis instrument, intended mainly as a transmitter tester for production lines and for the development of wireless communication equipment.
RF and sweep signal generator rental in Monterrey
Rental of radio frequency (RF) signal generators and sweep generators in Monterrey, Nuevo León, for testing electronic equipment, communications, RF and microwave systems. We have equipment that generates signals with controlled frequency, amplitude and modulation, for sensitivity testing, frequency response testing and the characterization of receivers, filters, amplifiers and other electronic circuits.
High-frequency spectrum analyzer rental in Monterrey
High-frequency spectrum analyzers in Monterrey, Nuevo León, for measuring and analyzing RF and microwave signals. They evaluate frequency, power, harmonics, spurious signals, bandwidth and other characteristics of electrical signals when testing transmitters, receivers, amplifiers, filters, communication systems and electronic equipment. Renting is a practical alternative for laboratories, maintenance and engineering projects that require specialized instrumentation.
Real-time signal power analyzer rental
The real-time signal power analyzer for LTE instantly captures, displays and analyzes radio frequency (RF) signals used in 4G LTE networks, with detailed information on their behavior and quality. It evaluates signal power, frequency, bandwidth, modulation, spectral occupancy and signal characteristics, and makes it easier to detect interference, level variations and other anomalies that can affect telecommunications performance.
Noise figure analyzer for amplifiers
The Keysight N8973A, an Agilent/HP NFA, is a noise figure analyzer for making fast, accurate and repeatable measurements over a range of 10 MHz to 3 GHz. It characterizes the noise behavior of RF devices and systems and delivers parameters such as Noise Figure (NF), Noise Factor and gain. It is a specialized tool for evaluating amplifiers.
Radio frequency counter rental up to 26.5GHz in Monterrey
We offer rental of radio frequency counters up to 26.5 GHz for accurately measuring and verifying RF signals in telecommunications, electronics, laboratory work, maintenance and equipment development. They determine the frequency of RF signals and allow functional testing, diagnostics and characterization of systems operating up to 26.5 GHz.
HackRF One software-defined radio rental
We rent the HackRF One with immediate delivery. It is an SDR (Software Defined Radio) transceiver for analyzing, receiving and transmitting radio frequency signals over a wide frequency range. It is used for RF testing, spectrum analysis, wireless system development, protocol research, transmitter and receiver validation and SDR application development, with different modulations and signals through specialized software.
Network analyzer (VNA) calibration and verification
7 mm APC7 VNA calibration kit rental
The Keysight 85050C is a precision mechanical calibration kit for vector network analyzers (VNAs) with a 7 mm interface. It is used to characterize and correct systematic errors in RF and microwave measurements. It operates from DC to 18 GHz and includes precision standards for two-port calibrations (Open, Short and Load) and a 50 Ω precision air line for TRL (Thru-Reflect-Line) calibration. It also includes adapters, connector gauges and torque wrenches, to achieve consistent connections and maintain measurement accuracy and repeatability.
Complete system rental: VNA, ECal, mechanical calibration kit and 75 ohm phase-stable cables
We offer rental of a complete system for 75 Ohm RF measurements. It combines a VNA, an ECal module, a mechanical calibration kit and 75 Ohm phase-stable cables, configured to work as a single measurement system. It allows you to characterize cables, filters, splitters, couplers, attenuators, connectors and other CATV components without separately acquiring the equipment and calibration accessories. The configuration is delivered with the available documentation for the instruments and accessories, to make test preparation easier and support repeatable measurements in engineering, validation and quality control projects.
Keysight type N calibration kit rental in Monterrey
We offer rental of the Keysight 85054B mechanical calibration kit in Monterrey, Nuevo León, for calibrating and verifying network analyzers and RF measurement systems. It provides the mechanical elements needed to establish reference conditions during calibration and helps maintain accuracy and repeatability in parameters such as S11 and S21. It is an option for laboratories, engineering departments and technicians who calibrate RF equipment without buying the kit outright.
85064A type N electronic calibration module
The Keysight 85064A available for rent (originally manufactured under the HP / Agilent brand) is a legacy microwave electronic calibration (ECal) module. It simplifies, speeds up and automates the calibration of vector network analyzers (VNAs). It provides continuous coverage from 1 GHz to 18 GHz and uses 50 ohm type N connectors.
Keysight 85053B verification kit for VNAs
The Keysight 85053B verification kit for rent is a set of high-precision standards that confirms a vector network analyzer (VNA) is operating within its factory technical specifications. It covers a frequency range of 300 kHz to 26.5 GHz and uses 3.5 mm connectors.
HP 85062A electronic calibration kit in Monterrey
The HP 85062A is an electronic calibration (ECal) module that operates from 1 GHz to 26.5 GHz with 3.5 mm connectors. It automates the calibration of vector network analyzers (VNAs), reduces human error and speeds up one-port and two-port measurements in the laboratory and in production.
Keysight 85052B standard mechanical calibration kit, 26.5 GHz, 3.5 mm
The Keysight (Agilent/HP) 85052B is a metrology-grade standard mechanical calibration kit. It characterizes and removes the systematic errors of vector network analyzers (VNAs) with 3.5 mm interfaces, over a frequency range from DC (direct current) to 26.5 GHz.
Vector network analyzer on the Smith chart
A vector network analyzer (VNA) uses the Smith chart as its main visual tool to show the magnitude and phase of the reflection coefficient (S₁₁ or S₂₂) simultaneously. In this way it measures the complex impedance of a high-frequency (RF) circuit at a glance.
Impedance, LCR meters, accessories and materials
Agilent 4291B impedance and material analyzer
The Keysight (Agilent/HP) 4291B RF material/impedance analyzer measures surface-mount components and dielectric/magnetic materials with high accuracy. It uses a direct-current voltage measurement technique, as opposed to the reflection technique, to measure impedance more accurately over a wide impedance range.
High-precision LCR meter rental up to 30 MHz in Monterrey

The Keysight 4285A Precision LCR Meter is a high-precision impedance analyzer for characterizing electronic components and materials. It measures inductance, capacitance, resistance, impedance, dissipation factor and quality factor (Q) over a range of 75 kHz to 30 MHz, for research, development, production and laboratory work. It is used to evaluate capacitors, inductors, transformers, filters, dielectric materials and impedance networks, and to analyze components as a function of frequency.
HP / Agilent / Keysight 4263B LCR meter rental
The HP / Agilent / Keysight 4263B is a benchtop LCR meter, a cost-effective, high-speed solution for automated production lines and for basic applications in development laboratories. Although the manufacturer considers it obsolete, it remains in high demand for its reliability in characterizing passive components.
Agilent 16191A SMD test fixture
The Agilent 16191A (now under the Keysight brand) is a test fixture for SMD components with lateral electrodes (side electrode). It is designed to accurately evaluate impedance, capacitance and inductance at high frequencies.
Keysight 16194A high-temperature component fixture
The Keysight 16194A is a specialized test fixture that measures the impedance of electronic components under extreme temperature conditions.
Agilent 16085B rental for electronic component testing
The Agilent / Keysight 16085B is a Terminal Adapter. It does not hold components directly: it acts as a high-precision mechanical and electrical conversion bridge.
16039A Binding Post Fixture rental for electronic components

Rental of the Keysight 16039A Binding Post Fixture for measuring and characterizing electronic components up to 250 MHz. It provides practical, reliable connections for measuring capacitors, inductors, resistors and other devices with compatible impedance analyzers and LCR meters, in tests that require measurements of impedance and electrical parameters at high frequency.
16190A 7mm performance test kit for impedance analyzers
The Keysight 16190A is a 7 mm test kit for verifying impedance analyzers and high-frequency measurement systems. It allows you to check performance and validate the accuracy of the measurement system in RF and microwave applications. Together with an impedance analyzer, it characterizes components and devices through parameters such as complex impedance, resistance, reactance, magnitude and phase.
7 millimeter APC7 air line rental for verification and material measurement
We offer rental of 7 mm APC-7 air lines for verifying and measuring materials with RF and microwave characterization systems. They allow high-precision measurements of impedance, dielectric properties, permittivity, dielectric loss and other electromagnetic parameters, for laboratories, research centers and industrial applications that require specialized equipment and accessories.
Rental of equipment for permittivity testing of dielectric materials in Monterrey
Rental of Keysight equipment for permittivity testing and dielectric characterization of materials, for laboratories, research centers and companies that evaluate the electrical properties of materials without investing in specialized instrumentation. They measure relative permittivity (ε′), loss factor (tan δ), dielectric loss (ε″), impedance and frequency response, with suitable accessories and methods for each type of material.
Antennas, couplers and electromagnetic fields
Triaxial RF electromagnetic field meter rental
We rent triaxial electromagnetic field (RF) meters for evaluating exposure levels and measuring electric and electromagnetic fields in different environments. They measure isotropically with triaxial probes, so there is no need to orient the sensor by hand in different directions. They are useful for radio frequency exposure studies, verification of telecommunications installations, evaluation of antennas and transmitters, and electromagnetic safety inspections.
Electromagnetic radiation (EMF) detector rental in Monterrey
We offer rental of electromagnetic radiation (EMF) detectors for measuring electric and magnetic fields quickly and simultaneously. The instrument detects field levels over a frequency range of 5 Hz to 3500 MHz, with a digital reading on an LCD screen and a data hold function. It is used to inspect radiation sources around electronic equipment, electrical wiring, high-voltage lines and communication systems, for diagnostics, inspection and preliminary assessment of electromagnetic exposure.
Near-field EMI probe rental in Monterrey
We rent near-field probe kits for EMC in Monterrey, Nuevo León. They are used to locate and analyze sources of electromagnetic interference (EMI) in electronic equipment, PCBs, cables and power supplies during diagnostics and development. They allow EMI troubleshooting, identifying areas of higher electromagnetic radiation and determining possible emission sources before formal electromagnetic compatibility testing.
Radio frequency directional coupler rental
Rental of radio frequency (RF) couplers in Monterrey, Nuevo León, for testing and measuring RF and microwave systems. Directional couplers take a controlled sample of the signal to measure forward power, reflected power, voltage standing wave ratio (VSWR) and other parameters when characterizing transmitters, amplifiers, antennas, filters and transmission lines. We have different configurations and frequency ranges for laboratory work and development.
Log-periodic antenna rental in Monterrey
The Aaronia HyperLOG 7040 is a passive, directional, broadband log-periodic antenna (LPDA) with a range of 700 MHz to 4 GHz, 50 Ω impedance and an SMA connector. Aaronia specifies it for mobile measurement, signal location and laboratory applications; it can also be used with spectrum analyzers for RF analysis. It has a typical gain of approximately 4 dBi, and calibration data are available for more accurate field measurements.
LB-159-10-C-SF horn antenna rental in Monterrey
The horn antenna is a high-frequency telecommunications device: a metal waveguide whose cross section gradually widens in the shape of a cone, pyramid or horn. This transition matches the internal impedance of the transmission line to free space and allows radio waves and microwaves to be emitted or received with high directivity and minimal losses.
Fiber optics
Fiber optic line analysis equipment rental
Quad OTDRs (single-mode and multimode in one device) are used for the analysis, certification and maintenance of fiber optic networks. Because they integrate both technologies, they work with the four standard wavelengths: 850/1300 nm for short-distance multimode (MM) links in data centers, and 1310/1550 nm for long-distance single-mode (SM) links and telecommunications.
OTDR launch spool rental in Monterrey
An OTDR launch spool (also called a launch box or test extension cable) is a reel of optical fiber of known length that is connected between the OTDR and the network under test. It shifts the OTDR’s initial dead zone into the spool, so that the loss, reflectance and condition of the first connector and the first meters of the actual link are measured accurately.
Low-cost fiber optic OTDR rental in Monterrey
“All-in-one” single-mode optical time-domain reflectometer (OTDR) for fiber optic network technicians and FTTH projects. It operates at the standard wavelengths of 1310/1550 nm with a dynamic range of 26/24 dB, enough to measure, diagnose and locate breaks in dark fiber links of between 60 and 100 kilometers.


































