75 Ohm VNA Rental with ECal and Mechanical Calibration Kit

Rental of a 75 Ω vector network analyzer with ECal, mechanical calibration kit, phase-stable cables and RF accessories. For RF and telecommunications engineers with projects of defined duration.

75 ohm vector network analyzer with connector

75 Ω VNA rental for RF and telecommunications projects

Buying a vector network analyzer can be a considerable investment when it is only needed for one specific project. That is why we offer 75 Ω VNA rental, with calibration accessories and the items needed to measure RF networks.

The configuration can include ECal, a mechanical calibration kit, phase-stable coaxial cables and accessories, all for the 75 ohm system, according to the requirements of each project.

This option is for laboratories, manufacturers, integrators, telecommunications companies, RF engineers and research and development departments that need to measure for a set period without buying the entire system.

Fully configured measurement system

Renting a configured system saves you from sourcing each element of the measurement separately.

A VNA alone is not necessarily a complete measurement system. To obtain consistent results, the cables, calibration standards, connectors, adapters, ECal modules and other accessories in the RF path must also be considered. That is why we configure the rental according to the work required.

The configuration can include:

75 Ω VNA + ECal + calibration kit + phase-stable cables + RF accessories.

The final configuration depends on the frequency range and the connectors required.

ECal for fast calibrations

One option is to work with Electronic Calibration (ECal).

ECal prepares the VNA through an electronic calibration controlled by the measurement system itself. It reduces the number of connections compared with certain procedures that use mechanical standards. It is convenient when several consecutive measurements are made and a stable test setup must be maintained.

The ECal module is supplied according to VNA compatibility and the characteristics of the application.

Mechanical calibration kit

For applications that require calibration with physical standards, we can provide a mechanical calibration kit. These kits can include standards that establish the reference of the measurement system and compensate for systematic errors in the RF path.

The type of kit must be selected according to impedance, frequency range and connector type.

In a 75 Ω application it is important not to use 50 Ω accessories as if they were equivalent, because impedance is a fundamental part of the measurement conditions.

Phase-stable RF cables

The system can include phase-stable cables, to maintain more consistent behavior during measurements.

Conventional cables can vary when they are moved or flexed. Where phase and amplitude matter, these variations can alter the results. That is why cables are selected according to the frequency range, the connectors and the application. Appropriate cables also help maintain a reproducible setup between measurement sessions.

Calibrated equipment and available documentation

Rental equipment is managed with its corresponding identification and documentation. Depending on the equipment and the contracted service, information on its calibration and traceability can be provided.

If the project requires formal documentation, you can specify at the quotation stage that you need certificates, calibration records or documentary evidence for the instruments and accessories used.

Where an instrument’s certificates come from accredited laboratories, the documentation may include references to bodies or laboratories such as Perry Johnson Laboratory Accreditation and traceability to NIST, strictly in accordance with the scope stated in each certificate.

Evidence of equipment condition

For projects with tighter document control, we can provide evidence of the identification of the equipment and of the accessories supplied. The aim is to let you relate the equipment received to its documentation. This serves companies with internal quality procedures, audits, supplier validation or engineering project documentation.

S11, S21, S12 and S22 measurements

The VNA can characterize two-port networks when the setup and the device under test allow it. S-parameters provide fundamental information on the behavior of an RF device.

  • S11: reflection at the input port.
  • S22: reflection at the output port.
  • S21: forward transmission.
  • S12: reverse transmission.

These measurements can be used to analyze insertion loss, return loss, transmission and phase behavior.

Applications for 75 Ω systems

This rental configuration serves projects related to:

  • CATV: characterization of components and coaxial networks.
  • RF television: evaluation of signal distribution devices.
  • Telecommunications: testing of passive components and RF systems.
  • Filters: evaluation of transmission and rejection within a frequency range.
  • Splitters and combiners: characterization of losses and port-to-port behavior.
  • Attenuators: verification of insertion loss and matching.
  • Coaxial cables: evaluation of transmission and reflection.
  • Connectors and adapters: characterization of RF behavior.

Rental for short-term projects

Renting can make more sense than buying a VNA when the equipment is needed only for a test campaign, product development, diagnostics or a temporary project. In addition, renting the system with its accessories saves you from buying cables, standards and calibration modules separately.

We can quote different configurations according to the time required and the accessories needed.

Separate ECal rental

If you already have a compatible VNA, you can also request ECal rental or other available calibration accessories. This is useful when the instrument is operational but a specific calibration is needed for a project.

Compatibility must be verified first: VNA model, frequency range, connectors and impedance.

Laboratory service as an alternative to rental

If you prefer not to operate the VNA, we also perform the measurements in our laboratory. You deliver the device under test and we handle the setup, calibration and measurement. Results can be delivered with graphs and technical documentation, depending on the contracted scope.

You choose between renting the system to run the tests in-house or requesting the laboratory measurement service.