Keysight Agilent 85052B: 26.5 GHz, 3.5 mm Mechanical Calibration Kit

Kit of precision standards for calibrating network analyzers at the 3.5 mm interface, for RF laboratories and engineers.

Keysight Agilent 85052B 26.5 GHz mechanical calibration kit with 3.5 mm interface

What the 85052B kit includes

The HP 85052B mechanical calibration kit contains precision standard devices for characterizing the systematic errors of HP network analyzers at the 3.5 mm interface. It also includes adapters for changing the test port gender, connector gauges for checking and maintaining the interface, and a torque wrench for proper connection.

Main specifications

  • Frequency range from DC to 26.5 GHz.
  • Calibration standards for performing a full two-port calibration.
  • Torque wrenches for connecting the standards correctly.
  • Adapters for changing the test port gender.
  • Commercial calibration certificate.

Standards in the kit

Broadband loads

These are metrology-grade terminations optimized for performance up to 26.5 GHz. Their rugged internal structure provides high connection repeatability. A distributed resistive element on sapphire provides stability and return loss.

Offset opens and shorts

These are built from precision-machined parts. The inner conductors of the offset short are one piece, as are the shorting planes, which gives highly repeatable connections. The offset opens have inner conductors supported by a low-dielectric material. Constant plastic material to minimize the compensation values.

In both opens and shorts, pin depth is tightly controlled, which minimizes phase errors. The offset lengths are designed so that the phase difference of their reflection coefficients is approximately 180 degrees at all frequencies.

Adapters

Like the other devices in the kit, they are manufactured to very tight tolerances to give good broadband performance and stable, repeatable connections. The beads are designed to minimize return loss and are spaced far enough apart to reduce interaction between them. Their nominal electrical lengths are equal, which allows them to be used in calibration.

Sliding loads

These are designed for excellent performance from 3 GHz to 26.5 GHz. The inner and outer conductors of the airline are precision machined. Besides their exceptional return loss, their load stability qualifies them as high-performance devices.

The sliding load allows the inner conductor to be extended for connection and then retracted to a preset pin depth. This reduces the chance of damage during connection and maintains a minimum pin depth to optimize performance.