Electromagnetic radiation tester (EMF meter) rental

EMF meter for detecting electric and magnetic fields in industrial environments, electrical installations and electronic equipment. For inspection and maintenance.

Electromagnetic radiation tester (EMF meter) for rent

We rent electromagnetic radiation testers for detecting and measuring electromagnetic fields in industrial environments, electrical installations and electronic equipment. They let you inspect exposure levels and locate radiation sources, for safety assessments, maintenance, diagnostics and installation checks.

Main features

Electromagnetic field measurement: measures electric and magnetic fields at the same time and gives a quick assessment of the levels in the area. When values exceed the reference levels configured in the instrument, it can issue an alert.

Applications: electromagnetic radiation inspections around mobile phones, computers, televisions, household appliances, electrical wiring, electronic equipment and high-voltage lines or conductors. It is practical for preliminary inspections and for locating sources of electromagnetic fields.

Simple operation: a digital LCD display shows the detected values directly. This makes field inspections easier, as well as comparing points to identify areas with higher field levels.

Built-in electromagnetic sensor: incorporates electric and magnetic field sensors. Values are processed electronically and shown on the display.

Data retention: the Data Hold function temporarily freezes the reading on the display so it can be recorded and analyzed. This is useful in hard-to-reach locations or when values must be documented.

Technical specifications

Feature Specification
Instrument type Electromagnetic radiation detector / EMF meter
Material ABS
Color Black
Electric field 1 to 1999 V/m
Electric field resolution 1 V/m
Magnetic field 0.01 to 99.99 μT
Magnetic field resolution 0.01 μT
Bandwidth 5 Hz to 3500 MHz
Display 3½-digit LCD
Sampling time Approximately 0.4 seconds
Measurement mode Simultaneous electric and magnetic field measurement
Operating temperature 0 to 50 °C
Operating humidity <80 % RH

Note: alarm or reference values must be interpreted according to the manufacturer’s specifications and the exposure standard or criterion that applies to the measurement. This instrument is for detection and inspection of electromagnetic fields, but it must not be used as a substitute for a certified measurement system when regulatory or compliance measurements are required.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer