4291B RF material and impedance analyzer rental in Monterrey

The Keysight (Agilent/HP) 4291B measures surface-mount components and dielectric and magnetic materials from 1 MHz to 1.8 GHz. For engineers evaluating impedance and materials.

Keysight 4291B RF material and impedance analyzer

Material and impedance analyzer rental

The Keysight (Agilent/HP) 4291B RF material/impedance analyzer measures surface-mount components and dielectric and magnetic materials easily and with high accuracy. Unlike the reflection technique, it uses a DC voltage measurement, which gives a more accurate impedance measurement over a wide impedance range.

Measurement and accuracy

  • Basic impedance accuracy is +/- 0.8 %.
  • High Q accuracy allows low-loss components to be analyzed.
  • An internal synthesizer sweeps frequency from 1 MHz to 1.8 GHz with 1 mHz resolution.
  • A 1.8 m error-free cable connects the analyzer to a test station. This lets you move the test point away from the analyzer without losing accuracy.
  • Advanced calibration and error compensation remove measurement error factors at the devices. They ensure high accuracy and repeatability on the DUT/MUT.

Control and bias

The 4291B controls the level automatically and monitors the test signals with the IBASIC programming function. Devices can be measured at constant voltage or constant current. With the optional DC bias (up to 40 V and 100 mA) you can measure bias-dependent impedance characteristics. At the press of a button, the built-in equivalent circuit analysis calculates the circuit constants of five models.

Channels, display and storage

It has two measurement channels. Each channel can measure a single impedance parameter (for example, Z) or a dual one (for example, Z-theta). The color TFT display, with split screen, shows the active traces and the memory traces (stored in RAM). A built-in floppy disk drive saves test programs and data in LIF or MS-DOS format.

With built-in IBASIC, the 4291B controls external test equipment, such as a temperature chamber or a wafer probe, without a separate instrument controller.

Material evaluation

The 4291B makes material evaluation easier and improves its quality and efficiency. It offers dielectric and magnetic material measurements over a wide frequency range (1 MHz to 1 GHz).