Transformers, motors and insulating oil
TTR analysis for transformer testing
Turns ratio (TTR) analysis is an essential test for assessing the electrical condition of power and distribution transformers. It verifies that the ratio between the primary and secondary windings matches the design values. It thus detects deviations caused by shorted turns, open circuits, incorrect connections, tap changer (TAP) faults, or damage from overloads and electrical stress.
Transformer and motor testing in Monterrey
Transformer and motor analysis is used to assess the reliability, efficiency and safety of electrical systems in industry, commerce and infrastructure. Tests applied include insulation resistance, turns ratio (TTR), winding resistance, vibration analysis, phase balance and thermal evaluation. These detect incipient faults before they cause unplanned shutdowns or costly damage.
Oil dissipation factor and power factor analysis in Monterrey
We analyze the dissipation factor (tan δ) and power factor of dielectric oil to assess the condition and quality of the insulation system of transformers and other electrical equipment. The test detects signs of moisture, contamination, aging and deterioration of the oil’s dielectric properties. It provides useful information for the diagnosis and preventive maintenance of high-voltage equipment, and helps detect changes in dielectric behavior.
Transformer oil analysis: power factor in Monterrey
We perform power factor (tan delta) tests on dielectric oil to assess the condition and quality of the liquid insulation of transformers and other electrical equipment. They detect signs of moisture, contamination, aging and oil degradation that can affect its dielectric properties and the reliability of the system. The measurements are useful for the diagnosis and preventive maintenance of transformers. See also the surface resistance tests on conductive, dissipative and insulating materials.
Dissipation factor and power factor tests on insulating oil
These tests assess the dielectric condition of the oil in electrical transformers. They detect contamination, moisture and insulation degradation, which helps prevent failures, optimize maintenance and extend the service life of the equipment. They provide information on the overall condition of the insulation system and on incipient problems before they develop into critical failures. They are used in predictive and corrective maintenance programs, reduce downtime and operating costs, and support the reliable operation of transformers, circuit breakers and other high-voltage equipment.
Electrical resistance analysis and testing of liquids using direct current (DC)
The electrical resistance test of liquids using direct current (DC) evaluates the dielectric properties of insulating oils and other fluids in electrical equipment. It helps detect contamination, moisture and degradation of the liquid, and maintain reliable insulation and good performance in transformers and other power equipment. The results make it possible to monitor the condition of the fluid over time, make predictive maintenance decisions and prevent failures that compromise the continuity and safety of electrical operation.
Density analysis of liquids and lubricants in Monterrey
We measure the density, that is, the mass per unit volume, of dielectric oils, industrial lubricants, fuels, solvents, hydraulic fluids, chemical products and other industrial liquids. Density is a fundamental parameter for quality control, identifying contaminants, verifying technical specifications and assessing the condition of fluids during their service life. The tests are performed with high-precision instrumentation and internationally recognized methodologies.
Cables, insulation and high voltage
Dielectric analysis of substation XLPE cables in Monterrey
We perform specialized analysis and testing on XLPE-insulated power cables in electrical substations to assess their condition, performance and reliability. Depending on the cable and the project requirements, the studies can include measurements of insulation, resistance, dielectric losses, capacitance and other electrical parameters. They make it possible to identify possible signs of degradation, moisture, aging or deterioration of the insulation.
Hipot testing of substation cables in Monterrey
The Hi-Pot test on substation cables verifies the insulation integrity of medium- and high-voltage cables using controlled test voltages. It helps detect defects and prevent electrical failures in power distribution and transmission systems. It is performed with specialized equipment that evaluates the insulation without compromising the integrity of the cable, and provides information for commissioning, preventive maintenance and the safe operation of electrical infrastructure.
Hipot testing under liquid immersion in Monterrey
We evaluate the electrical insulation integrity of components and materials exposed to liquids. A high voltage is applied between the conductive parts and the insulation system while the specimen remains immersed in the specified liquid. This evaluates leakage current, dielectric breakdown and insulation resistance under immersion. It is useful for electrical and electronic components that will operate in, or be exposed to, oils, water or other liquids during their service life.
Partial discharge analysis of insulation in Monterrey
Partial discharge analysis detects insulation faults in medium- and high-voltage electrical equipment. It identifies problems before they cause major damage or critical failures, and helps prevent unexpected interruptions in operation. It also helps extend the service life of transformers, cables and electric motors, and supports more efficient preventive maintenance.
Partial discharge analysis with an ultrasound camera in Monterrey
We use ultrasonic cameras to detect and locate partial discharges in electrical equipment and installations. The technique identifies ultrasonic emissions associated with possible insulation problems, electrical connections, corona effect and other phenomena that can indicate abnormal conditions. It can be applied in substations, electrical panels, transformers, lines and medium- and high-voltage equipment, to locate points of interest and support diagnostics and preventive maintenance.
Electrical protection relay testing in Monterrey
We test and verify Siemens protection relays in Monterrey, Nuevo León. We evaluate the operation and configuration of SIPROTEC 5, SIPROTEC 4 and Reyrolle 5 relays: protection functions, settings, inputs and outputs, trip signals, timers and operating logic, according to the system application. These tests are fundamental in the commissioning, maintenance, diagnosis and periodic verification of substations and electrical installations.
Power quality and efficiency
Power system quality services in Monterrey
We analyze the behavior of installations to detect problems that can affect equipment, industrial processes and distribution systems. We measure and analyze voltage, current, frequency, harmonics, power factor, unbalance, transients and voltage variations. With this we identify disturbances, evaluate system performance and establish corrective actions that improve the reliability and efficiency of the installations.
Power quality: unbalance in the electrical system in Monterrey
We analyze voltage and current unbalance to identify variations between phases that can affect performance and reliability. The measurements make it possible to evaluate phase behavior, detect unbalanced loads, identify possible problems in electrical distribution and determine their impact on motors, transformers, variable frequency drives and other three-phase equipment. The study provides technical information for diagnosing and correcting the problems.
Power quality fluctuations in Monterrey
We analyze voltage fluctuations as part of power quality studies. We identify rapid and sustained variations in system voltage level that can affect equipment and industrial processes. The measurements detect voltage variations, repetitive fluctuations and phenomena associated with flicker, and determine their behavior and possible impact on lighting, motors, electronic equipment, automation and sensitive loads.
Flicker measurements in Monterrey
We measure flicker as part of power quality studies. We evaluate the voltage fluctuations that cause perceptible or repetitive variations in lighting intensity and that can affect sensitive equipment. The analysis determines the magnitude, frequency and behavior of the variations, identifies possible sources of disturbance and evaluates their impact on the installation. The results provide technical information for diagnosing voltage stability problems.
Photovoltaic inverter efficiency analysis
We evaluate the energy performance of inverters in solar generation systems. We compare the input power from the photovoltaic array with the electrical power delivered at the inverter output. The measurements analyze voltage, current, active power, power factor, frequency, conversion efficiency and behavior under different load conditions, and identify losses or conditions that affect the use of the energy generated.
Energy testing of photovoltaic panels in Monterrey
Photovoltaic panel tests verify the performance, safety and operation of solar systems. Specialized measurements detect faults, optimize energy generation and extend the service life of the installation. They also help verify compliance with standards and technical specifications in residential, commercial and industrial systems.
Energy loss analysis and calculations in Monterrey
We calculate electrical energy losses to identify and quantify the technical losses of distribution systems, industrial installations, substations and electrical networks. We analyze current, voltage, power factor, conductor resistance, connected loads and operating conditions. In this way we determine Joule-effect losses, voltage drops and opportunities to improve energy efficiency. The studies make it possible to optimize electricity consumption and reduce operating costs.
Grounding, safety and training
NOM 022 STPS grounding studies in Monterrey
We carry out studies and measurements of grounding systems to evaluate their resistance and operating conditions in electrical installations, workplaces, substations and protection systems. The measurements identify conditions that can compromise the safety of the installations and support electrical maintenance and verification programs. The studies can be performed taking into account the applicable requirements of NOM-022-STPS-2015.
DC3 courses on grounding and soil resistivity in Monterrey
DC-3 course on grounding, soil resistivity and lightning rod systems. It focuses on the evaluation of grounding systems, the measurement of soil resistivity, the identification of conditions that affect electrical safety and the criteria for installing, inspecting and maintaining lightning protection systems. Certifications endorsed by the STPS.
DC-3 certifications for industrial electrical safety and analysis in Monterrey
DC-3 certifications in Monterrey for technical, electrical and maintenance personnel. The programs can include vibration and machinery analysis, grounding system studies, insulation analysis, power quality studies and electrical safety. The courses strengthen technical skills, promote safe work practices and support personnel training in line with the applicable STPS requirements.
Electric arc service: Arc Flash suits in Monterrey
We rent out Arc Flash suits, designed to protect against the thermal effects of an electric arc. We have suits, jackets, pants, face shields, hoods and protective accessories, which are selected according to the risk level and the characteristics of the job. The right equipment helps reduce exposure to thermal energy, projectiles and other hazards of an arc event, in work on electrical panels, substations, motor control centers and the like.
In-tank certification of dielectric gloves in Monterrey
The tests are performed in accordance with the applicable requirements of ASTM D120. We inspect and certify dielectric gloves for electrical work, and verify their integrity and insulating capacity with applied voltage tests (High Potential Test). The process detects possible leakage currents, punctures, insulation deterioration and other conditions that compromise user safety.
Electrical safety testing of medical equipment in Monterrey
We perform electrical safety tests on medical equipment, electromedical equipment and portable devices: insulation resistance, ground continuity, Hi-Pot tests and leakage current measurement, in accordance with the applicable requirements of IEC 60601-1 and with electrical safety inspection methodologies. We evaluate the condition of the insulation and protection systems to identify conditions that may pose risks to patients, operators or technical personnel.
Electromagnetic fields
Electromagnetic field studies on high-voltage lines
We carry out studies and measurements of low-frequency electromagnetic fields associated with high-voltage lines. We evaluate electric and magnetic field levels on land, in industrial buildings and at installations close to electrical infrastructure. The measurements can be made at different distances and heights to characterize the field distribution and compare the results with the limits or technical criteria applicable to the project and with the requirements of the relevant authority.
Electromagnetic radiation analysis in Monterrey
Electromagnetic radiation analysis evaluates the levels of electric and magnetic fields generated by electrical equipment and installations. The measurements help verify compliance with current regulations, identify possible risks and maintain a safe environment for personnel and operations. They are used to identify emission sources and quantify their intensity under different operating conditions. The results are presented in technical reports that make it easier to apply mitigation measures and meet national and international electromagnetic safety standards. More information in the electromagnetic radiation analysis with an EMF meter.
Electromagnetic radiation (EMF) analysis with field meters
At Creativeit we perform electromagnetic radiation (EMF) analysis by measuring electric fields, magnetic fields and power density generated by electrical and electronic equipment, transmission lines, substations, data centers, industrial systems, telecommunications antennas and radio frequency devices. We use high-precision EMF meters and electric and magnetic field detectors to assess exposure to non-ionizing radiation, identify sources of electromagnetic interference (EMI) and verify compliance with the limits set by standards.
Surface resistance
Surface resistance analysis of conductive materials
This test evaluates the ability of a surface to conduct or dissipate electrical charges. It helps verify technical compliance and detect anomalies in materials. It is used for the quality control of coatings, floors, packaging and components used in areas sensitive to electrostatic discharge (ESD). The results make it possible to optimize manufacturing processes, ensure the repeatability of electrical performance and comply with national and international standards applicable to the electronics, automotive and manufacturing industries.
Vibration and thermography
Vibration analysis of machinery and motors in Monterrey
We diagnose machinery in Monterrey, Nuevo León: motors, pumps, fans, compressors, gear reducers and rotating equipment. The study identifies imbalance, misalignment, mechanical looseness, bearing problems and other anomalies that affect the operation and reliability of machinery. It provides technical information for detecting problems at early stages, supporting predictive maintenance and reducing the risk of unplanned shutdowns and costly failures.
Thermography analysis in Monterrey
Infrared thermography identifies hot spots and thermal anomalies in electrical installations. It also detects faulty connections and equipment at risk of failure. The inspection is carried out without interrupting system operation, which facilitates preventive maintenance and reduces downtime. The results are documented with thermographic images and detailed technical reports, so that corrective actions can be taken and maintenance programs can be optimized according to the actual condition of the equipment.
Thermography analysis or thermal imaging camera rental in Monterrey
We perform infrared thermography analysis of electrical installations and equipment with Level I Certified personnel. We identify hot spots, overloads, poor connections, phase unbalance and other conditions. The studies can be applied to substations, transformers, electrical panels, motor control centers, capacitor banks, harmonic filters and other industrial equipment. We also rent out professional thermal imaging cameras in Monterrey.