Environmental chambers to IEC 60068: climatic testing in Monterrey

Environmental testing to IEC 60068 in climatic chambers, to validate the reliability of equipment, components and materials. For design, quality and certification engineers.

Environmental chamber for climatic testing to IEC 60068

Environmental testing to IEC 60068

IEC 60068 is the international reference standard for environmental testing of equipment, components and materials. It evaluates their behavior, performance and reliability under controlled, severe environmental conditions.

In the laboratory, it makes it possible to simulate real operating, storage and transport conditions, with repeatable, traceable results for design, certification and quality control.

What the IEC 60068 standard is

IEC 60068 (Environmental Testing) is a series of standards from the International Electrotechnical Commission (IEC) that defines:

  • Test methods
  • Controlled environmental conditions
  • Exposure procedures
  • Severity and duration criteria

It is applied in the electrical, electronics, industrial, automotive, aerospace and telecommunications sectors.

Tests covered

Temperature tests

  • IEC 60068-2-1 – Test A: Cold
  • IEC 60068-2-2 – Test B: Dry heat
  • IEC 60068-2-14 – Test N: Change of temperature

They evaluate expansion, contraction, thermal fatigue and functional stability.

Humidity tests

  • IEC 60068-2-30 – Damp heat, cyclic
  • IEC 60068-2-78 – Damp heat, steady state

They are used to analyze corrosion, ion migration, dielectric failures and material degradation.

Combined temperature–humidity tests

  • Simulation of tropical conditions and harsh environments
  • Evaluation of seals, encapsulants and protective coatings

Typical test parameters

  • Temperature: −40 °C to +150 °C (depending on the method)
  • Relative humidity: up to 98% RH
  • Duration: from hours to extended cycles
  • Control: continuous and programmable

Laboratory equipment

The following are used to perform IEC 60068 tests:

  • Laboratory climatic chambers
  • Programmable temperature and humidity controllers
  • Calibrated, traceable sensors
  • Data logging systems

Sun Systems climatic chambers make it possible to meet IEC 60068 methods, with stable, uniform and repeatable test conditions.

Benefits

  • Objective validation of product design
  • Fewer field failures
  • International regulatory compliance
  • Improved reliability and service life
  • Technical support for certifications

Common applications

  • Electronic components
  • PCBs
  • Sensors and actuators
  • Insulating and ESD materials
  • Industrial and control equipment

Testing services

  • Testing to IEC 60068
  • Development of test profiles
  • Execution in climatic chambers
  • Detailed technical reports

For additional technical information, specific scopes or a test quotation, speak with the engineer.

Metrological temperature control

In our environmental analyses and tests where temperature is a critical parameter, we verify our thermal systems in-house. Each test is backed by temperature validation in our dry-well calibrator, which has these characteristics:

  • Operating range: -30 °C to 150 °C.
  • Resolution: 0.01 °C.
  • Thermal stability: ±0.02 °C.
  • Display accuracy: ±0.1 °C.
  • Block uniformity: horizontal ≤ ±0.05 °C, plus controlled vertical gradient.

This is how we confirm the stability, uniformity and accuracy of the test conditions. The expanded uncertainty of the system is determined according to the operating point, the sensor under test and the process conditions.

We do real tests, on video! Watch them on our YouTube channel →