Aging and thermal cycling
Accelerated aging tests
They evaluate the reliability and service life of components, circuit boards and devices under controlled environmental conditions. Cycles of temperature, humidity, thermal stress and continuous operation identify premature failures, material degradation and performance problems before they occur in the field. These tests serve the development, validation and quality control of industrial, automotive, aerospace, medical and telecommunications products.
Thermal cycling and thermal shock in Monterrey
We evaluate the reliability, durability and performance of electronic components, materials, electrical devices and industrial products subjected to extreme temperature changes. We simulate real operating and transport conditions and identify failures from thermal expansion and contraction, material fatigue, delamination, solder joint cracks and component degradation. The high-precision environmental chambers run programmable temperature profiles in accordance with international standards such as IEC 60068-2-14, MIL-STD-883 and JESD22.
Thermal cycling programs to evaluate accelerated component life
Our thermal cycling programs in Monterrey accelerate the aging of electronic and electrical components and materials. They reproduce years of thermal operating conditions in a short period. Controlled temperature variations identify premature failures, thermal fatigue, solder joint cracks, delamination, deformation and material degradation before the product reaches the end user. The tests make it possible to evaluate reliability, estimate service life, optimize designs and validate manufacturing processes in accordance with international standards.
Climatic chambers and temperature control
Analysis in climate-controlled chambers in Monterrey
We perform climate-controlled test analysis to evaluate the performance, reliability and resistance of electronic equipment, electrical components, materials and devices under controlled temperature and humidity. These tests identify premature failures, material degradation, insulation problems, corrosion, condensation and operating variations caused by extreme environments. Our laboratory in Monterrey has high-precision climatic chambers to simulate real operating conditions.
Analysis in high-precision, high-stability climate-controlled chambers
They evaluate the performance of materials, components and equipment under controlled temperature and humidity. They help verify reliability, stability and compliance with technical specifications in industrial and laboratory applications. They include thermal cycling, accelerated aging tests and functional tests during environmental exposure, to identify changes in device behavior. They are used to validate designs, develop products and improve quality and durability in demanding applications.
Electronics measurement with temperature control in Monterrey
We perform electronic tests under controlled temperature conditions to evaluate the performance, stability and reliability of components, devices and systems under different thermal conditions. These tests identify behavior variations, possible failures and changes in electrical parameters associated with temperature. They provide information for design validation, product development and reliability evaluation.
Electronic testing in environmental chambers in Monterrey
We perform electronic tests in temperature chambers under controlled environmental conditions to evaluate the performance, stability and reliability of components, boards, equipment and systems under different thermal conditions. These tests identify behavior variations, potential failures and changes in electrical parameters. They provide information for design validation, product development, reliability testing and performance evaluation under controlled environmental conditions.
Temperature and humidity tests to verify corrosion in Monterrey
Temperature and humidity tests with electrical bias to evaluate corrosion in electronic components. Devices are subjected to controlled temperature and humidity while a voltage is applied during the test. The tests evaluate electrochemical corrosion, ion migration, dendrite growth, insulation degradation and electrical failures that can develop when a component operates with humidity and bias. They apply to PCBs, electronic components, connectors, insulation materials and electronic assemblies.
Vacuum, pressure and altitude
Tests in an acrylic vacuum chamber in Monterrey
Electronic tests in vacuum chambers to evaluate the operation and performance of components, boards, equipment and systems at reduced pressure. They identify failures, changes in electrical behavior, insulation problems and heating when equipment operates in a vacuum. They are useful in industrial, aerospace, electronics and reliability applications.
Pressure, high vacuum and altitude tests in Monterrey
Pressure, vacuum and altitude simulation tests in specialized environmental chambers. They reproduce the operating conditions of equipment and components at low atmospheric pressure or controlled pressure. They evaluate the performance, reliability and integrity of electronic devices, electrical components, lithium batteries, sensors, connectors, packaging and sealed systems exposed to changes in altitude or vacuum.
Integration with electrical measurement
Integration of environmental analysis with advanced electrical measurement
We combine the monitoring of environmental variables with analysis of the behavior of electrical and electronic systems. We simultaneously evaluate temperature, humidity, pressure, vibration, noise, air quality and climatic conditions, together with voltage, current, power, harmonics, power quality, insulation resistance and electrical performance.
Other electrical tests
TTR tests, transformer turns ratio in Monterrey
Noise and breathing air studies
Sound studies: exposure evaluation, NOM-011-STPS-2001
We perform sound studies and evaluate occupational noise exposure in workplaces, using the criteria of NOM-011-STPS-2001. The measurements identify the noise levels to which workers are exposed, with sound level meters and dosimeters according to the characteristics of the study. The service covers recognition of the work areas, measurement of sound levels and evaluation of exposure.
Noise studies with digital sound level meter and dosimeter in Monterrey
We perform occupational and environmental noise studies with high-precision digital sound level meters and dosimeters with graphing capability, such as Simpson instruments. We evaluate sound pressure levels and daily noise exposure in industrial, commercial and construction environments. The measurements make it possible to determine compliance with NOM-011-STPS, identify high-noise areas and establish control measures to protect workers’ hearing health.
Air filling for personal breathing tanks in Monterrey
We fill breathing tanks for industrial applications. We supply the breathing air required by protective equipment and by work in environments where a safe air source is needed. The service keeps available the tanks used by industrial personnel, emergency brigades and activities with respiratory protection systems.














