Electrical characterization of conductive and insulating materials

Tests to determine a material's ability to conduct or insulate electric current. For R&D, quality and material validation teams.

Electrical characterization test of conductive and insulating materials

Electrical performance of materials

Conductive and insulating materials are fundamental to virtually every electrical and electronic system. Knowing their electrical properties makes it possible to select the right material for each application and optimize product design.

At Creativeit Labs we perform electrical characterization of materials to determine their ability to conduct or insulate current. The results support research, development, quality control and material validation processes.

Tests we perform

Volume resistivity

We determine the material’s internal resistance to the passage of current. This information is essential for evaluating insulating, semiconducting and conductive materials for industrial and electronic use.

Surface resistivity

We evaluate the resistance to current flow across the surface. This test is indispensable for materials used in electronic devices, coatings, packaging and electrostatic discharge (ESD) protection applications.

Electrical conductivity

We determine the material’s ability to carry current. This makes it possible to classify conductive, semiconducting and insulating materials according to their electrical properties.

Electrical resistance

We test components and materials to verify continuity, integrity and electrical performance during manufacturing or research.

Characterization under different environmental conditions

We evaluate electrical behavior taking into account:

  • Temperature
  • Relative humidity
  • Exposure time
  • Accelerated aging
  • Controlled environmental conditions

These tests show the electrical stability of the material over its service life.

Characterization over a wide frequency range

Depending on the application, we evaluate electrical behavior from direct current (DC) up to high frequencies to analyze variations in the material’s properties.

Materials we evaluate

  • Engineering plastics
  • Conductive polymers
  • Antistatic materials
  • Dissipative materials
  • Insulating materials
  • Technical ceramics
  • Epoxy resins
  • Silicones
  • Elastomers
  • Composite materials
  • FR4 laminates
  • PCBs
  • Insulating tapes
  • Conductive coatings
  • Conductive paints
  • Thin films
  • Encapsulation materials
  • Materials for automotive electronics

Applications

  • Research and development (R&D)
  • Quality control
  • Supplier validation
  • Development of new materials
  • Electronics industry
  • Automotive industry
  • Telecommunications
  • Aerospace
  • Medical devices
  • Research centers
  • Universities
  • Electronic component manufacturing

Benefits of testing

  • Determines whether a material meets the electrical requirements of the application.
  • Identifies degradation from moisture, temperature or aging.
  • Reduces the risk of electrical failures during operation.
  • Optimizes material selection.
  • Increases the reliability of electronic products.
  • Facilitates the validation of new materials before implementation.
  • Provides technical information for certification and development processes.

Parameters we can measure

  • Volume resistivity
  • Surface resistivity
  • Electrical conductivity
  • Electrical resistance
  • Leakage current
  • Capacitance
  • Impedance
  • Dielectric constant
  • Dissipation factor (Tan δ)
  • Dielectric strength (depending on the type of material)
  • Electrical response as a function of frequency

Why Creativeit Labs

  • High-precision measuring equipment.
  • Specialized instrumentation for materials characterization.
  • Staff with experience in electrical and electronic engineering.
  • Custom tests according to the needs of each project.
  • Complete technical reports, with analysis and interpretation of results.
  • Service to the industrial, electronics, automotive, energy, aerospace and research sectors.

If you need to evaluate the electrical properties of conductive, dissipative or insulating materials, contact us for technical advice and a test proposal tailored to your project.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer