Operating principle
The phenomena being simulated (electrostatic discharge, bursts, lightning surge) are transients of different energy and shape. All generators share a similar architecture: a high-voltage source charges a capacitor, a high-speed switch discharges it, and a network of resistors, capacitors and inductors determines the rise time and pulse duration, as well as the source impedance.
What defines each type
- Electrostatic discharge: a very fast, low-energy pulse, applied by contact or through air with a gun.
- Fast burst: packets of pulses with very short rise times and a high repetition rate, with low energy per pulse.
- Surge: a slower pulse with more energy, using a combination wave of voltage and current.
Why source impedance is part of the definition
The waveform the equipment receives depends on the load. That is why the standards specify the internal impedance of the generator, so that the test is equivalent between laboratories. Two generators with the same output voltage but different impedance produce different pulses on the same equipment.
Verification
The waveform is verified with an oscilloscope of sufficient bandwidth, connecting a load or calibration target to the generator and, where applicable, attenuators. Rise time, duration and amplitude are checked, along with the frequency and duration of the packets in the case of bursts. Verification is repeated periodically because switches and components wear out.
How it is coupled to the equipment
Coupling/decoupling networks are used to inject the pulse into power or signal lines without it returning to the mains, along with clamps or specific accessories. The generator alone does not define the test: the coupling, the reference plane and the cable arrangement are part of the method.
This equipment produces high voltages and must be operated by qualified personnel, in accordance with the applicable safety regulations.