Electrostatic discharge (ESD) testing in Monterrey
We perform electrostatic discharge (ESD) immunity testing on electronic devices and equipment at our laboratory in Monterrey. We use a Kikusui KES4021A electrostatic discharge simulator to assess whether the equipment under test (EUT) withstands ESD events without losing functionality, degrading in performance or suffering permanent damage.
ESD testing is part of electromagnetic compatibility (EMC). It reproduces the electrostatic discharges that can occur during the handling, installation and operation of electronic products. Electrostatic charge buildup can produce high-voltage, high-current pulses with extremely fast rise times, capable of affecting sensitive circuits, interfaces, control systems and components.
ESD testing to IEC 61000-4-2
The test can be performed with the two main methods of IEC 61000-4-2:
- Contact discharge: the simulator tip is placed directly on the EUT test point to obtain controlled, repeatable events.
- Air discharge: the discharge tip is brought toward the EUT until an electric arc forms. This simulates conditions closer to certain real handling events.
The method, voltage levels, polarity, number of discharges and application points are determined by the standard, the product specification or the customer requirement.
What we assess during the test
During the test we monitor how the device behaves at different discharge levels and check for:
- Temporary or permanent loss of functionality.
- Equipment resets or lockups.
- Disturbances in signals, communications or interfaces.
- Operating errors or abnormal behavior.
- Automatic recovery after the discharge.
- Permanent damage to components or circuits.
The test can be supplemented with documentation of the test conditions, the application points and the behavior observed during the discharges.
ESD immunity assessment
Testing makes it possible to identify design vulnerabilities, grounding problems, protection shortcomings and points sensitive to electrostatic discharge. This information helps improve the EMC robustness of the product before release or certification.
We perform ESD testing on components, electronic boards, electronic equipment, control systems and industrial products, with procedures adapted to the device under test and the applicable technical requirements.