Oscilloscopes and probes in inventory
We have professional measuring equipment and accessories, new and used, at our Monterrey store for immediate rental. We carry high-performance portable and benchtop oscilloscopes, for sale or rent. If we do not have the model you need, we order it.
We do not carry student, Chinese or pocket oscilloscopes. Only professional equipment from recognized brands: Agilent, Keysight, Tektronix, Lecroy, Fluke and Rohde & Schwarz.
Oscilloscopes are available for immediate delivery. If we do not have the model you want, delivery of new equipment is in most cases under 5 business days. If you contact us today, you can rent your oscilloscope the same day.
Probes and accessories
We have a large assortment of probes for digital oscilloscopes: differential, active, current or high-voltage. We also have clamp-on current probes and low-capacitance, high-frequency active probes. If you need another one, just ask. We carry special probes, accessories and cables for any equipment.
How we work
- Rentals include a technician experienced in using the equipment, so that you get the most out of it from the very first minute.
- We perform tests and analysis of all kinds, electrical and electronic. Laboratory tests are carried out in the customer’s presence and we record our procedures on video. Our work is 100% transparent.
- No imports and no waiting times.
- We are active field engineers, not mere salespeople. We advise you on the equipment or accessories your measurement requires.
We have worked at companies such as Panasonic, Navistar, Husmann, General Electric, Pemex, Latina, US Motors, International and Heineken. We have personnel holding seaman’s books for access to oil platforms, and experience in the mining industry.
YouTube channel: www.youtube.com/user/electronicatutorial
Fluke 190-504, 500MHz, 4 channels
The Fluke ScopeMeter 190 II Series is a portable oscilloscope that combines safety and ruggedness with the performance of a benchtop oscilloscope. It is designed for plant maintenance engineers and technicians, and it works in harsh, dirty and hazardous industrial environments, to analyze everything from microelectronics to power electronics systems.
The 190 II Series models include a multimeter, paperless TrendPlot and ScopeRecord recording modes, and a hands-free system with Connect-and-View triggering.
Main features
- Two or four electrically isolated inputs.
- Safety rating CAT III 1,000 V / CAT IV 600 V.
- Models with 60 MHz, 100 MHz or 200 MHz bandwidth.
- Sampling rate up to 2.5 GS/s with resolution down to 400 ps.
- Memory of 10,000 samples per channel for waveform capture, to focus on the details.
- Dedicated 5,000-count digital multimeter on two-channel models.
- Quad measurements through the BNC inputs on four-channel models.
- Continuous Connect-and-View trigger alert for single-shot, pulse-width and video triggering.
- ScopeRecord roll recording mode: captures waveform data for up to 48 hours.
- TrendPlot: trends measurement readings for up to 22 days.
- Advanced automatic power measurements VPWM, VA, W, PF and time (mAs, V/s, w/s).
- Dust- and liquid-proof, IP-51 protection.
- Isolated USB ports for connecting memory devices and a PC.
- Slot for anchoring and locking the oscilloscope with a standard Kensington device if it will be left unattended.
Battery
Lithium-ion battery for extended operating time.
- 190-X04, up to 7 hours on four-channel models. BP291 included as standard.
- 190-XX2, up to 4 hours on two-channel models. BP290 included as standard, or up to 8 hours with the optional BP291.
- The spare battery can be charged with the EBC290 external charger.
- The battery door is easy to reach, which makes replacement simple.
Portable oscilloscopes with FFT
These instruments are intended for designers integrating wireless connectivity into their products. They combine oscilloscope and spectrum analyzer functions in a single device. They capture and measure analog, digital and RF signals to show the complete system, and they help debug design complications quickly.
We also rent with a technician included, so that the equipment delivers from the very first minute. Our technicians have experience on oil platforms and in the mining industry. For more information call 81-24593364 or the emergency cell phone 811-786-07-68, or come directly to our premises.
Other analysis and measurement equipment for rent
We rent electronic analysis and measurement equipment for any budget:
- Digital and analog oscilloscopes.
- Spectrum analyzers.
- Vector network analyzers (VNA).
- Signal generators.
- OTDRs, power meters and optical meters.
- Frequency counters.
- Dynamic, vibration and audio analyzers.
- Hitasteis.
- LCR meters and optical equipment.
- Vector signal analyzers (VSA).
- Calibration and verification kits.
- Micrometers for RF and microwave connectors.
- Curve tracers.
Oscilloscope manufacturers
- Agilent HP
- Tektronix
- Rohde & Schwarz
- Anritsu
- Fluke
- Acterna JDSU
- Advantest
- Keithley
- Marconi IFR Aeroflex
- LeCroy
Video about the programs and tools of an oscilloscope and how it works: www.youtube.com/watch?v=rrYEFtgK_kg
LeCroy WaveRunner oscilloscope rental
The WaveRunner Xi-A series is a problem-solving oscilloscope, from 400 MHz to 2 GHz. It offers a large display, small footprint, fast viewing, SMART and serial data triggering, scanning, and WaveShape analysis capabilities for fast or slow signals.
Main functions
- Triggering on I2C, SPI, UART, RS-232, LIN, CAN or FlexRay serial data patterns. It decodes the values on the oscilloscope grid and lets you correlate the decoded data streams with other events in an embedded control system (optional).
- Sequence mode: divides the acquisition memory into segments to capture specific events over long periods. Each segment is then viewed and analyzed separately.
- An extensive collection of SMART, serial and digital triggers (MS series) quickly isolates the events of interest. Some are optional.
- WaveScan locates unusual events in a single capture, or searches for them across many acquisitions over a long period, with more than 20 search and scan modes. ScanHisto and ScanOverlay display the scanned results.
- The WaveStream fast viewing mode, with a high sample rate, characterizes signal shape, rise time and overshoot, and verifies the presence or absence of high-speed transients.
- Your own measurements and math functions with Excel, MATLAB or VBScripts. Some capabilities are optional.
- Advanced application packages for specific problems.
Long memory and analysis beyond time
The WaveRunner Xi-A’s long memory is optimized to calculate more information 10-100x faster than other oscilloscopes. The front panel gives simple access to zoom and positioning.
Multi-domain signal analysis converts the information to the statistical domain (histogram), the spectral domain (long-memory FFT), jitter, modulation or other measurement parameter domains (parameter tracks). Some capabilities are optional. LeCroy’s math, measurement and analysis tools are integrated with the oscilloscope’s basic operations.
A wide variety of probes is available: active FET, current, differential and high-voltage, with complete tip and ground accessories.
Mixed signal (oscilloscope option)
The MS series captures digital signals at speeds up to 500 MHz. It displays up to 36 digital channels with up to 50 Mpts/Ch of memory, and analyzes analog and digital events together.
Power amplifier measurements
Thanks to its overload recovery and signal integrity, the WaveRunner Xi-A is well suited to measuring high-voltage switching losses, conduction losses, and power supply ripple and switching, among other measurements. It is used with LeCroy differential amplifiers for a high-performance common-mode rejection ratio of 100,000:1.
Timing characterization and slow and fast signals
Extensive triggers isolate an event quickly. Timing is measured statistically and behavior is viewed in histograms, to understand the real cause.
Long memory, the HFREJ trigger, coupling and built-in noise filtering quickly reveal the behavior of circuits that mix low-speed signals (sensor, actuator, power supply, mechanical) and high-speed signals.
WaveRunner Xi-A: performance and display
With 5 GS/s and 12.5 Mpts standard on each channel (up to 10 GS/s interleaved with the 64Xi-A, 104Xi-A and 204Xi-A), you get accurate measurements of fast signals and long captures of low-speed events.
The 10.4-inch color display leaves room for everything, including time-correlated mixed-signal views and non-time-domain analysis. It has a good viewing angle and a very small footprint, which makes it easy to work anywhere.
The waveform analysis capability gathers statistical data from thousands or millions of events, converts signal information to the statistical, modulation or frequency domain, or uses WaveScan to find anomalous events. In addition, the WaveRunner Xi-A has numerous application packages for specific tests and measurement challenges.
Efficient validation and debugging
The WaveRunner MXi-A provides the performance and tools to debug and validate your signals, and it goes deeper into testing to understand the causes of complex problems. It includes the debugging and analysis tools of the Xi-A models, plus advanced math and measurements, timing analysis, and custom math and measurements.
- Analog bandwidths from 400 MHz to 2 GHz.
- Advanced math and measurement capabilities.
- Jitter and timing analysis.
- Custom math and measurements.
Embedded controller validation and debugging
WaveRunner Xi-A oscilloscopes become high-performance mixed-signal oscilloscopes (MSOs) with the MS-500 or MS-250 options. With the I2C, SPI, UART, RS-232, LIN, CAN and FlexRay trigger and decode options, the instrument works as a trigger, acquisition unit and analyzer for analog, digital and serial data.
Designing and debugging embedded controllers involves capturing analog, digital and serial signals from analog sensors, microcontrollers and peripherals. The MS-500 captures digital signals at speeds up to 500 MHz and has 50 Mpts/Ch of memory. It supports 36 channels: enough to view all the signals of a 16-bit microcontroller plus some control lines. For applications that do not require maximum performance, the MS-250 offers a maximum signal speed of 250 MHz, 18 channels and 10 Mpts/Ch.
Extensive triggering
The MS-500 and MS-250 extend the triggering capabilities of the WaveRunner Xi-A. Cross-pattern triggering lets you configure simple or complex patterns with any combination of analog and digital channels. An event can be armed on an analog signal and triggered on a digital pattern.
Simple setup
Unlike a traditional logic analyzer, the MS-500 and MS-250 are easy to use. A simple connection joins the oscilloscope to the digital inputs and you can start debugging right away. Standard tools such as cursors, measurement parameters and zoom remain available.
I2C, SPI, UART, RS-232, LIN, CAN and FlexRay serial triggering
Isolates specific serial data events from the embedded controller. Trigger conditions are configured in binary or hexadecimal format (symbolic for CAN). With the MS-500 or MS-250, serial data buses are captured and the analog channels stay free for other uses. You can also trigger at specific locations in long I2C EEPROM reads.
Conditional data triggering
Conditional data triggers for I2C, UART, RS-232, LIN or FlexRay let you select a range of DATA values, not just one value. In I2C, data bytes usually specify subaddresses for accessing memory locations in EEPROM. The conditional trigger makes it possible to trigger on a range of bytes corresponding to reads or writes in specific memory blocks. It is also useful for monitoring the data outputs of sensors, such as analog-to-digital converters, and triggering when the data leaves a safe operating range.
Summary table, search and zoom
The oscilloscope works as a protocol analyzer with a protocol information table, which can be customized or exported to Excel. Touching a message in the table zooms the instrument in on the detail. You can also search by address or specific data values in the acquisition.
Color-coded decode overlay
The software breaks the waveform down into binary, hexadecimal or ASCII protocol information and overlays the decoded data on the waveform. Protocol sections are color-coded for easier reading. Decoding is fast, even with long acquisitions.
Acquisition
Fast throughput
The X-Stream II architecture offers high data throughput. It uses variable waveform segment lengths so that all intensive calculations take place in the CPU cache, which improves speed and efficiency. The result is faster processing than on other oscilloscopes.
Long memory
X-Stream II has essentially no restrictions on analysis memory length, whatever the type of analysis, because the waveform segment length can always be limited to a size that fits in the CPU cache. Oscilloscopes with conventional architectures usually have limitations: at best they analyze 5-20% of their acquisition memory length.
Responsiveness
The WaveRunner Xi-A series allocates buffers dynamically to maximize available memory and offers fast front-panel response. A built-in processing abort attends to panel changes instantly: it stops the current process and lets you position or zoom new waveforms without a long recalculation. Meanwhile, the waveform preview shows provisional results.
SMART triggers
The WaveRunner Xi-A offers a multitude of basic and advanced (SMART) triggers. Advanced triggers isolate specific events and, combined with long memory, give a complete view of signal activity around that event. You can trigger on what is expected (widths, glitches, video, logic patterns) and also on unusual signals (dropouts, intervals, runts, slew rates). LeCroy’s exclusion discards normal signals and captures only abnormal ones, which speeds up debugging. Signals down to 1 ns wide can be triggered on (500 ps for width and glitch triggering), or an A condition can be used to qualify a B trigger.
TriggerScan
TriggerScan uses high-speed hardware triggering with persistence to capture only the signals of interest and deliver answers up to 100x faster than other methods. Traditional fast display update modes work best with frequent events and slow edges. TriggerScan excels at finding infrequent events with fast edges. A built-in automatic trigger trainer analyzes the waveforms, identifies normal behavior and sets up a large set of smart rare-event triggers aimed at abnormal behavior. It then cycles through them in sequence, with a user-defined dwell time, and captures and displays any anomalous signal that meets the conditions.
Sequence mode
Sequence mode stores up to 10,000 triggered events as segments in the oscilloscope’s memory. It is used to capture many fast pulses in quick succession (when trigger rearm time matters) or a few events separated by long periods (when capture time matters). It can acquire 4 channels at once, provides timestamps for each acquisition (with 1 ns resolution) and minimizes capture dead time (800 ns). Combined with an advanced trigger, it isolates a rare event, captures all its instances over hours or days, and lets you view and analyze them later.
LeCroy WaveStream: fast viewing mode
WaveStream offers an intensity-graded display (256 levels) with fast updating, closely simulating the appearance of an analog oscilloscope. It helps visualize signals with jitter or anomalies, or perform a visual check before creating an advanced trigger or a WaveScan setup.
The sampling rate in WaveStream mode reaches 10 GS/s (up to 5x that of other oscilloscopes), which makes it a good glitch and runt finder. Timing jitter is often evaluated visually to understand approximate behavior, and WaveStream makes it easy to see jitter on edges or in eye diagrams. It also lets you relate composite behavior (WaveStream) to single-event behavior (real-time sampling): you capture in WaveStream mode, switch to single trace to view or zoom, and return to WaveStream.
WaveScan: advanced search and analysis
Not even a good trigger finds every unusual event; sometimes a more powerful capability is needed. WaveScan locates unusual events in a single capture (capture and search), or searches for them across many acquisitions over a long period. You choose from more than 20 search modes (frequency, rise time, runt, duty cycle, etc.), apply a condition and start the scan.
Because the scan modes are not simple copies of the hardware triggers, they are more useful. For example, no oscilloscope triggers on frequency, but WaveScan can scan on frequency. This builds up a data set of unusual events separated by hours or days. A LeCroy X-Stream oscilloscope scans millions of events quickly. WaveScan on the WaveRunner Xi-A includes ScanHisto and ScanOverlay. The events found are overlaid in a ScanOverlay view for easy comparison, and the measurement-based scan modes let ScanHistograms show the statistical distribution of the events found.
Measurement and validation
The WaveRunner Xi-A serves for everyday characterization, validation and debugging, and for fast debugging of advanced problems. It is useful when debugging circuits with low- and high-speed signals, when verifying the integrity of high-speed clock and data signals, or when debugging complex problems.
Often, viewing the signals does not give the precision needed to validate designs. That is when getting accurate statistical data quickly matters. With the WaveRunner Xi-A, data from thousands of measurements accumulates in a single trigger (it does not limit measurements to one value per acquisition) or over multiple acquisitions. One button shows the statistics and another a graphical histogram view of the measurement distribution, which can be zoomed. Up to 2 billion measurement events accumulate, or measurable persistence traces can be created with the optional WRXi-STAT.
Advanced math
Most oscilloscopes have only a few simple math functions, such as subtracting waveforms or performing low-resolution FFTs on short records. Others offer long memory but limited capacity to process it. WaveRunner Xi-A oscilloscopes have dozens of standard math functions and capabilities such as long-memory FFT, trends, tracking (optional), sparsing, interpolation, selection, a variety of persistence views, and custom math and measurements (MATLAB or Visual Basic formats). Other specialized capabilities are also available in optional application packages.
Multi-domain analysis
The hardest problems in a circuit are rarely obvious in the time domain. Long memory with zoom, search and scan is part of the solution. Converting time-domain information to the statistical, parameter or frequency domains leads to the root of the problem faster.
Trend views: the oscilloscope as a strip-chart recorder
Slow sampling at 1000 seconds/div captures hours of low-speed signal data. Trend views plot measurement values of high-speed signals alongside slower signals, such as transducer or voltage values.
Track views: parameters versus time
Track on the WaveRunner Xi-A (optional) uses every instance of a measurement in an acquisition to create a plot of measurement values on the Y axis and time on the X axis, correlated with the original channel acquisition. Examples:
- Measure the frequency of a signal over a 100 ms interval and see whether the frequency changes occur at the correct times.
- Measure the pulse width of a modulated signal (PWM) over a 1 second interval and determine whether the modulation circuit reacts properly to system changes.
- Measure cycle-to-cycle jitter values on a microprocessor and see how their peaks correlate with peaks on the power lines.
Histograms
LeCroy oscilloscopes capture hundreds or thousands of times more measurements per acquisition than others. With that much data, a list of mean, minimum, maximum and standard deviation is not enough. Histograms show the statistical distribution and give a real view of the underlying problems. For example:
- Measure millions of jitter values in seconds, see whether the distribution is Gaussian or not, and correct timing problems to stay within a timing budget.
- Better validate timing budgets when measuring embedded controller response times: hundreds of thousands of timing events instead of hundreds, and real-world worst-case situations.
FFT: spectral views
LeCroy’s long memory (up to 25 Mpts) increases your ability to understand signal behavior in the frequency domain. It delivers 5 to 100x the frequency resolution of FFTs on other oscilloscopes, for more precise troubleshooting. Built-in FFT averaging helps remove random events from the calculations. LeCroy FFTs can be applied to any channel or math function. Examples:
- Capture power supply, clock and data signals with 1 kHz frequency resolution, and correlate supply noise with signal integrity.
- Apply an FFT to a cycle-to-cycle jitter track and obtain information on the frequency components and the root cause of the instability.
- Capture hundreds of acquisitions and average the FFTs to increase the signal-to-noise ratio and separate random from deterministic events.
Optional software packages
Serial data compliance: QualiPHY packages
QualiPHY packages give step-by-step instructions for a broad set of serial data standards, such as USB 2.0 and Ethernet, with automated execution, illustrated instructions and complete reports for compliance testing.
Ethernet package (QPHY-ENET)
QPHY-ENET performs electrical compliance tests for 1000Base-T.
Electromagnetic compatibility package (WRXi-EMC)
The EMC package adds flexibility to the rise time, fall time and width parameters needed to accurately measure ESD pulses, EFT bursts, surges and transients common in EMC testing. It also allows histograms of up to 2 billion events, parameter math and measurement filtering.
Jitter and timing analysis package (WRXi-JTA2)
It uses specialized timing parameters to measure period, cycle-to-cycle, half period, width, etc., on a variety of signals. It employs the three jitter views (statistical, time and frequency) to understand the root cause. Histograms give the statistical view of the distributions. Tracks give the time view, showing correlated jitter peaks or modulations and comparing them with other signals. FFTs give the frequency view, for debugging the main causes of high jitter in the circuit.
Digital filter package (WRXi-DFP2)
DFP2 implements finite or infinite impulse response filters to remove unwanted spectral components, such as noise, and better examine the important signal components. The DFP2 option offers a standard set of FIR or IIR filters and the ability to design your own filters.
Math tools
Standard.