Active oscilloscope probe rental in Monterrey

Rental and sale of active, passive, current and differential oscilloscope probes, with their accessories, for design and test engineers.

Active oscilloscope probes for rent

Oscilloscope probes in stock

We have active, passive, current and differential oscilloscope probes in stock, with all their accessories, from brands such as Keysight, Agilent, HP, Lecroy, Tektronix and Rohde & Schwarz. We also sell or rent new and used equipment and accessories.

What active probes are

Active voltage probes contain active components, such as transistors and amplifiers, and need power to operate.

They have very low input capacitance, so they maintain a high input impedance over a wide frequency range. This allows measurements at test points of unknown impedance with much less risk of loading effects. With their low loading, they can be used in high-impedance circuits where passive probes would load the circuit too heavily. They are also less sensitive to the effects of inductance in long ground leads.

However, the active components have a more restricted maximum input voltage range, because of the limitations of the amplifier and the power supplies.

Tektronix P6243

Features

  • 1GHz bandwidth (probe only).
  • 1pf input capacitance.
  • 1MΩ input resistance.
  • Direct access to surface-mount components with pitch as small as 0.5 mm.
  • Measurements with CMOS, BiCMOS, ECL, GaAS and TTL logic.

Applications

  • High-speed digital system design.
  • Component design and characterization.
  • Manufacturing and test engineering.
  • Educational research.

Tektronix 6245

Features

  • 1.5 GHz bandwidth.
  • 1 pF input capacitance.
  • 1 MΩ input resistance.
  • Direct access to small 0.5mm surface-mount components.
  • Measurements with CMOS, BiCMOS, ECL, GaAs and TTL logic.

Applications

  • High-speed digital system design.
  • Component design and characterization.
  • Manufacturing and test engineering.
  • Educational research.

Lecroy AP020 FET Differential Probe

  • Configuration: Bandwidth: DC to 1000 MHz
  • Input Impedance: 1 MOhm
  • Input Capacitance: 1.8 pF
  • Attenuation: 10:1
  • Dynamic Range: 10 V
  • DC Offset Range: +/- 20 V
  • ProBus Compatible