How do you measure the capacitance of an in-circuit component?

To measure the capacitance of a component in circuit, you must discharge and de-energize the circuit and keep in mind that the other components connected in parallel also contribute to the measured value.

Limits of in-circuit measurement

A capacitance meter, normally an LCR meter, applies an AC signal to the component and measures the resulting current to calculate the impedance. In a circuit, the meter sees everything connected between its probes: the capacitor in question plus the other components in parallel with it, such as resistors, inductors, semiconductors and other capacitances. The result is an equivalent impedance, not that of the isolated capacitor.

Preparation

  1. De-energize the circuit and wait for the capacitors to discharge. Discharge large-value capacitors in a controlled way, because a charged capacitor can damage the meter and cause injury.
  2. Identify the parallel paths using the circuit schematic.
  3. Choose a test frequency and level suited to the capacitor type and the expected value. Large values are measured at low frequency and small ones at higher frequency. A high signal level can turn on semiconductors and alter the reading.
  4. Use appropriate contacts and leads, with open-circuit and short-circuit compensation to eliminate wiring parasitics.

How to interpret the result

  • If the reading is higher than the expected value, there are capacitances in parallel, such as those of other components or of the wiring.
  • If the dissipation factor or the phase angle is abnormal, a parallel resistive path is having an influence.
  • If the value varies with frequency more than normal, the component model or the surrounding circuit is not as expected.

When to isolate it

If the in-circuit measurement is not conclusive, one of the component’s leads is lifted so the rest of the circuit is no longer seen. This is common in fault diagnosis. Care must be taken during reinstallation so as not to damage traces or solder joints.

Component model

A real capacitor has equivalent series resistance and parasitic inductance. The meter offers series and parallel models; for high-value capacitors or those with significant losses the series model is preferable, and for small values, the parallel model. The specific values from the meter’s manufacturer appear in its manual.