24/7 emergencies 814 777 6921812 230 6079WhatsApp 811 786 0768
Electrónica MonterreyElectrónica MonterreyLaboratorios Creativeit Talk to an engineer
Menu

LCR meter rental with accessories

LCR meters and impedance analyzers for rent, with accessories for measuring components and testing them at high temperatures.

LCR meters with accessories for rent

LCR meters and accessories for rent

We rent LCR meters with accessories, such as the Keysight 4263B, 4285A and 4291B. We also have accessories for these instruments, such as the Agilent Keysight 16048A, 16065C, 16453A, 16334A, 16047C, 16047D and 16034E. They are suitable for all types of components: resistors, inductors, capacitors, transformers, diodes, etc. They make it possible to connect extensions or external accessories to LCR meters or impedance analyzers, even for testing components at high temperatures. We also have the Sencore LC103 and Sencore LC102 for measurements at different voltages.

LCR meter accessories

Measuring a resistance, a capacitance or an inductance requires special accessories. We offer accessories for the LCR meter, for resistance measurement and for impedance analysis. Additional components include measurement adapters, measurement cables, protection circuits and measurement interfaces for connecting software. The instruments’ special clip allows measured values to be evaluated accurately, for example in resistance measurements.

If you need to customize the measurement adapter or measurement cable, for example with a longer connecting cable for measuring resistances, speak directly with someone on our team.

In addition to the test adapters mentioned, there are gold-plated measurement cables with alligator clips for measuring capacitance and inductance. Calibration of the measuring instruments is carried out in a quality assessment laboratory. The laboratory also repairs measuring devices and replaces parts. Calibration is available for capacitance, inductance, resistance and other variables.

Component testing at high temperatures

In the research and development of electronic components and materials, the product development cycle has been shortened to meet end-user demand. As a result, greater importance is placed on better evaluating the temperature characteristic, which is key to the reliability and performance of the final product.

The temperature characteristic test kit is a new solution for measuring the temperature characteristic of components and materials. It is an option for material/impedance analyzers and covers a wide range of applications: from evaluating electronic materials used in RF components to measuring various impedance parameters of components and circuit board traces.

With a temperature drift compensation function, our impedance and material analyzers analyze the temperature characteristic with high accuracy over a wide range from –55 °C to +150 °C. With the 4291B we use high- and low-impedance test heads to cover wide impedance measurement ranges.

High-accuracy impedance measurement up to 3 GHz

  • The RF I-V method achieves a wide impedance measurement range.
  • Temperature characteristic measurements for electronic components.
  • Accuracy is improved by the temperature drift compensation function.
  • The temperature range covered is –55 °C to +150 °C.
  • Temperature characteristic measurements for dielectric and magnetic materials.
  • Several test fixtures are available for material measurements, such as the 16453A.
  • Compatible with the ESPEC (SU-261) temperature chamber.
We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer