What is phase in vibration analysis?

Phase indicates where a vibration is in its cycle relative to a reference, expressed in degrees, and it is used to determine how different points on the machine move relative to each other and to distinguish faults that have the same spectrum.

What it measures

Two vibrations of the same frequency can have equal amplitude and yet occur at different moments: one reaches its maximum when the other passes through zero. The difference in timing, expressed as a fraction of a cycle in degrees, is the phase. On its own, the phase of a single point means nothing: it is always measured relative to something.

How it is measured

  • With a reference on the shaft: an optical sensor and a reflective mark, or a proximity sensor and a notch, deliver one pulse per revolution. The phase is the delay between that pulse and the maximum of the 1X vibration.
  • With two channels: two accelerometers measure simultaneously at two points, giving the relative phase between them without the need for a reference on the shaft.

It is normally measured at a specific frequency, such as the rotating frequency, isolated from the rest of the signal.

What it is used for

  • Unbalance: the phase is stable and, on the same support, the horizontal and vertical readings differ by about a quarter of a turn.
  • Misalignment: usually shows a significant phase difference between the two sides of the coupling.
  • Resonance: when crossing a natural frequency, the phase changes sharply.
  • Looseness: unstable phase.
  • Balancing: it is the information that makes it possible to locate the angle at which to add or remove mass.

How to interpret it correctly

  1. Always measure with the same sensor, at the same point and in the same direction.
  2. Verify that the reference pulse is clean and stable.
  3. Measure with the machine in steady-state operation, because the phase changes with speed near a resonance.
  4. Set an angle convention, either with or against the direction of rotation, and keep to it.

What it does not do

Phase does not provide the diagnosis on its own; it is interpreted together with the amplitude, the spectrum and the context. A phase that seems inconsistent may be due to a poor reference pulse rather than a machine problem.