The approach
Identifying a transmitter means answering three questions: what signal it is, where it is and whether it should be there. They are answered in that order, with a spectrum analyzer, suitable antennas and knowledge of the band’s allocations.
1. Detect and characterize
The band is observed with a spectrum view and a waterfall view to see continuous and intermittent emissions. For each signal, record the center frequency, occupied bandwidth, level, modulation type when recognizable and time pattern: continuous, bursty or periodic. These features work as a fingerprint. A typical bandwidth and spectral shape allow you to suspect the type of equipment, such as a data link, a telephony system or a repeater.
2. Compare with what is expected
Using the country’s frequency allocation table and the list of users and your own equipment, you decide whether the emission is legitimate. A signal in a free-use band may be perfectly legal even if it does not belong to the site; a signal in a band assigned to a specific service, when the site does not use it, deserves attention. Spurious emissions or intermodulation products from known transmitters are also ruled out before blaming a third party.
3. Locate
- Level gradient: when moving with an antenna, the level rises as you approach the source.
- Directional antenna: rotating it until the maximum is found gives a direction; fading caused by reflections can be misleading, so it is advisable to measure from several points.
- Cross bearings: two or more directions taken from different sites intersect near the source.
- Gain reduction: an attenuator helps avoid receiver saturation when the source is close.
What to do with the result
A record with frequencies, times, levels, captures and directions of arrival is the basis for action. If the emission is illegal or harmful, the procedure is to inform the telecommunications authority; blocking or jamming the signal on your own is not permitted. Once the equipment has been identified, the matter can be resolved with the person responsible: reconfiguring the channel, removing the equipment or regularizing its operation.
Common mistakes
- Concluding that a signal is illegal without consulting the band’s allocation.
- Measuring at a single point and accepting the direction as correct.
- Not recording times, and losing the relationship with the emission pattern.
- Mistaking a harmonic or an intermodulation product for an independent carrier.