Dry-well rental, -30 °C to 150 °C, for calibrating temperature probes in Monterrey

Dry-well calibrator for rent to calibrate, verify and adjust thermocouples, RTDs and other temperature sensors, in the laboratory or at your facilities. For maintenance, quality and calibration.

Dry-well calibrator for temperature sensor calibration

Dry-well calibrator for sensors, thermocouples and RTDs

At Creative IT we rent dry-well calibrators for the calibration, verification and adjustment of temperature instruments, in the laboratory or directly at your facilities.

The equipment generates stable temperatures from -30 °C to 150 °C and can calibrate sensors used in the automotive, pharmaceutical, food, electronics, energy, petrochemical and manufacturing industries.

With its interchangeable inserts you can calibrate sensors of different diameters with stability, thermal uniformity and repeatability, which reduces test times.

Instruments you can calibrate

  • Type J, K, T, E, N, R and S thermocouples.
  • Pt100 RTD sensors.
  • Pt1000 sensors.
  • Temperature transmitters.
  • Digital thermometers.
  • Temperature indicators.
  • Industrial process sensors.
  • Laboratory instrumentation.
  • HVAC sensors.
  • Sensors for the pharmaceutical industry.
  • Sensors for food and beverages.
  • Temperature monitoring equipment.
  • Data loggers.

Dry-well features

Range of -30 °C to 150 °C

Suitable for refrigeration and industrial heating processes, it covers most of the points used in maintenance, validation and quality control.

Stability and uniformity

It is a stable thermal source, with repeatable results at each calibration point.

Inserts for various diameters

We have interchangeable inserts for different sensor sizes. They reduce heat transfer errors and make it easier to calibrate several instruments.

Digital control

The controller allows specific temperatures to be programmed with accuracy and repeatability.

Portable equipment

It can be used in the laboratory or in the plant, without removing instruments from the process.

Applications

  • Temperature sensor calibration.
  • Verification of digital thermometers.
  • Temperature transmitter calibration.
  • Industrial process validation.
  • Preventive maintenance.
  • Planned shutdowns.
  • Start-ups.
  • ISO 9001 audits.
  • Quality management systems.
  • Pharmaceutical validations.
  • Equipment qualification.

Benefits of renting

Renting a dry-well temperature calibrator is a cost-effective solution when you need to calibrate without investing in specialized equipment.

  • Lower cost than buying equipment.
  • Immediate availability.
  • Useful for temporary projects.
  • An option for audits and validations.
  • Reduced maintenance times.
  • Professional technology with no capital investment.
  • Specialized technical support during the rental.

Sectors we serve

  • Automotive industry.
  • Manufacturing.
  • Electronics.
  • Aerospace.
  • Energy.
  • Oil and gas.
  • Chemical industry.
  • Pharmaceuticals.
  • Food and beverages.
  • Calibration laboratories.
  • Research centers.
  • HVAC.
  • Industrial maintenance companies.

Technical support

In addition to the rental, our specialists can support you with:

  • Calibration procedures.
  • Technical advice.
  • Insert selection.
  • Equipment configuration.
  • Interpretation of results.
  • Preparation of technical reports.
  • Good measurement practices.
  • Recommendations for obtaining traceable, repeatable measurements.

Why rent from Creative IT

  • Professional calibration equipment.
  • Operating range of -30 °C to 150 °C.
  • Good thermal stability.
  • Inserts for multiple sensor diameters.
  • Equipment inspected and ready to operate.
  • Fast service in Monterrey and shipping throughout Mexico.
  • Options for laboratory work, industrial maintenance and field work.

We rent by the day, week or month. Talk to the engineer to choose the right equipment for thermocouples, Pt100 and Pt1000 RTDs, transmitters, digital thermometers and industrial sensors.

We do real tests, on video! Watch them on our YouTube channel →

Do you have a problem nobody has been able to measure?

Talk directly to the engineer in charge, with no middlemen.

Talk to an engineer