Fluke 750P29: 0 to 3,000 PSI (200 bar)
The Fluke 750P29 is used to calibrate and verify pressure gauges, pressure transmitters, pressure switches, indicators and hydraulic or pneumatic systems in critical industrial applications. Its range is 0 to 3,000 PSI (0 to 200 bar).
Because of its rugged design, its stability and its compatibility with Fluke process calibrators, it is used by calibration laboratories, industrial maintenance companies and instrumentation engineers who require repeatable, traceable results.
What the Fluke 750P29 is
It is a reference pressure module designed to work with the Fluke 754, Fluke 753, Fluke 725 and Fluke 726 process calibrators and the 750 series. It measures pressure with high accuracy in hydraulic and pneumatic systems.
Its high-stability sensor offers very low uncertainty, which is useful in work where precision is essential.
Applications
Calibration and verification of:
- Analog pressure gauges.
- Digital pressure gauges.
- Pressure transmitters.
- Pressure switches.
- Pressure indicators.
- Pressure calibrators.
- Process instrumentation.
- Hydraulic systems.
- Pneumatic systems.
- Calibration benches.
- Industrial test equipment.
Main features
Measuring range
- 0 to 3,000 PSI
- 0 to 200 bar
- 0 to 20 MPa
Suitable for medium- and high-pressure applications.
Accuracy
The Fluke 750P29 stands out for its accuracy, stability and repeatability. It serves as a reference when measurement uncertainty must be minimized.
Hydraulic and pneumatic systems
It can measure pressure with:
- Air.
- Nitrogen.
- Hydraulic oil.
- Distilled water (when the procedure allows it).
- Other fluids compatible with stainless steel.
Fluke compatibility
- Fluke 754 Documenting Process Calibrator.
- Fluke 753.
- Fluke 726.
- Fluke 725.
- Fluke 750 series.
Benefits of renting
Renting is an alternative when you need temporary calibrations without investing in reference equipment.
- High precision.
- Excellent stability.
- Repeatable results.
- Equipment ready to operate.
- Useful for audits.
- Useful for industrial maintenance.
- An option for temporary projects.
- Lower investment.
Sectors we serve
- Oil and gas.
- Energy.
- Chemical industry.
- Pharmaceutical industry.
- Manufacturing.
- Food and beverages.
- Mining.
- Industrial automation.
- Calibration laboratories.
- Maintenance companies.
- Research centers.
Rental conditions
Our pressure modules are inspected before each rental to verify their operation. We offer:
- Equipment ready to operate.
- Rental by the day, week or month.
- Technical advice.
- Immediate availability.
- Shipping throughout Mexico.
- Support for pressure calibration and industrial instrumentation.
Technical specifications
| Feature | Specification |
|---|---|
| Model | Fluke 750P29 |
| Type | Reference pressure module |
| Range | 0 to 3,000 PSI (200 bar / 20 MPa) |
| Medium | Pneumatic and hydraulic |
| Compatibility | Fluke 754, 753, 726, 725 and 750 Series |
| Applications | Industrial pressure calibration |
For rental rates by the day, week or month, talk to the engineer.