What it is and which installations it applies to
It is a mandatory Mexican official standard. Its purpose is to protect people and property against the risks arising from the use of electricity: electric shock, fire, overheating and faults. It refers to utilization installations: homes, shops, industries, public buildings and others where electrical energy is consumed.
What topics it covers in general
- Definitions and general installation criteria.
- Feeders, branch circuits and their overcurrent protection.
- Conductors: selection, identification and raceways.
- Grounding and equipotential bonding.
- General-use equipment: panels, transformers, motors, lighting.
- Locations with special conditions, such as areas made hazardous by gases or dusts, and particular conditions of certain premises.
- Special installations and alternative sources, such as on-site generation.
Its organization into chapters is similar to that of other installation codes, which makes it easier to locate a topic, but this is no substitute for reading the applicable text.
What it does not cover
It does not regulate the generation, transmission and distribution carried out by the supply company, which are governed by other provisions. Nor is it a design manual or a maintenance guide: it sets minimum safety requirements, not the optimal design for a specific case. A design that meets the minimum may be insufficient for the process.
How it is used in practice
In a project, it serves to define minimum conductor sizes, protective devices, the grounding scheme and raceway methods. When reviewing an existing installation, what is found is compared against the requirements, and typical findings are undersized conductors, poorly coordinated protection, missing ground connections or unidentified equipment. In certain cases, conformity assessment by an outside entity is required, depending on what the applicable regulation establishes.
What to do before applying it
Standards are updated. Before basing a design, an inspection or a technical opinion on it, consult the current edition and its transitional provisions, and verify which other standards and regulations apply to the type of installation. Work on energized installations must be done by qualified persons.