What does IEEE 519 establish on harmonic distortion?

IEEE 519 is a recommended practice that establishes how to limit harmonic distortion at the point of common coupling: it restricts the harmonic current each user injects and the voltage distortion the grid must maintain.

General scope

IEEE 519 is a recommended practice and set of requirements for harmonic control in electric power systems. Its central idea is shared responsibility: each user must limit the harmonic current it injects, and whoever supplies the power must keep voltage distortion within reasonable limits. If each user respects its part, total voltage distortion on the grid remains contained.

Point of common coupling

The limits are evaluated at the point of common coupling (PCC), where other users could be affected: normally the connection point between the installation and the grid. They do not apply to each individual piece of equipment inside the plant, or at arbitrary internal points.

How the limits are structured

  • Current: current distortion limits, per harmonic order and total, are determined by the ratio of the short-circuit current at the PCC to the user’s demand current. A grid that is stronger relative to the load is allowed more current distortion, because its effect on the voltage is smaller.
  • Voltage: individual and total voltage distortion limits depend on the voltage level at the PCC; the higher the voltage, the stricter the limits.
  • Demand reference: current distortion is expressed relative to the maximum demand current and not to the instantaneous current, which keeps a light load from appearing highly distorted.

How it is evaluated

The evaluation is statistical: measurements are taken over a representative period and percentile values are examined, with different treatment for short-duration conditions. Instruments must measure harmonics by a recognized method.

What an engineer sees in practice

A study under the standard defines the PCC, calculates the short-circuit ratio, chooses the applicable row of limits and compares it with the measurements. If the limits are exceeded, the next step is to evaluate whether to reduce the harmonic current at the source with filters, reactors or higher-pulse converters.

What to do with this summary

This guide describes only the general scope. The limit tables and precise definitions change between editions; consult the current edition before applying any value.