What does dBm mean?

dBm is the power level expressed in decibels relative to one milliwatt. Zero dBm equals one milliwatt, and every ten decibels up or down multiplies or divides the power by ten.

Definition and conversion

The level in dBm is obtained as ten times the base-ten logarithm of the power divided by one milliwatt. From there:

  • 0 dBm is one milliwatt.
  • A positive level is more than one milliwatt; a negative one, less.
  • 30 dBm is one watt.
  • Every 10 dB equals a factor of ten in power, and every 3 dB is approximately a factor of two.

To convert to watts, the formula is inverted: the power is one milliwatt multiplied by ten raised to the level divided by ten.

Why it is the usual unit in RF

Powers in a radio frequency laboratory range from tiny levels, such as those of a received signal, up to tens of watts in a transmitter. In dBm, that range is handled with short numbers, and the effects of gains and losses are calculated by addition and subtraction. Spectrum analyzers and power meters display dBm by default.

How levels are combined

Operation Is it valid? Result
dBm + dB Yes dBm
dBm − dBm Yes dB (a ratio)
dBm + dBm Not directly Convert to linear, add and return to dBm

As a qualitative example, two uncorrelated signals of equal level give a total power about three decibels higher than that of each one, not double the dBm figure.

Relationship with voltage

The power in a resistor is the RMS voltage squared divided by the resistance. In a 50 ohm system, the RMS voltage corresponding to a given level can be calculated from the power. This equivalence is valid only if the impedance is the one assumed and the signal is sinusoidal. With modulated or noisy signals, a distinction must be made between average and peak power.

What to watch for when reading a value

  • A spectrum analyzer shows the power within the resolution bandwidth; when comparing noise or wideband signals, the bandwidth matters.
  • The reading may not include the losses of external cables and adapters; if the level is needed at the device plane, they must be corrected for.
  • Do not confuse dBm with dBW (referred to one watt), dBc (relative to the carrier) or dBμV (referred to one microvolt).