Principle
A directional antenna receives more signal when it points toward the source. If it is connected to a spectrum analyzer or a receiver and rotated, the level of the interfering signal reaches a maximum on the bearing of the source. That bearing is a line of position. With two or more lines taken from different points, their intersection indicates the approximate location.
Procedure
- Identify the interfering signal in the spectrum: frequency, bandwidth, modulation type and behavior over time.
- Choose a directional antenna suited to that band and with compatible polarization.
- Rotate the antenna in azimuth and note the bearing of the maximum. If the level is very high, use an attenuator to avoid saturating the receiver, because close to the source the maximum becomes flat.
- Move and repeat the bearing from another position.
- Cross the lines and approach the estimated area until the origin is located.
What the engineer sees
The level rises when the antenna points at the source and falls when it points away, and the shape of the antenna’s main lobe determines the accuracy of the bearing. On many antennas the maximum is broad and the minimum is sharper, so some technicians find the bearing by averaging the points where the level drops by an equal amount on each side of the maximum.
What causes errors
- Reflections from buildings and metal structures that make the source appear to be in another direction.
- Side lobes and the antenna’s limited front-to-back ratio, which produce secondary maxima.
- Misaligned polarization, which reduces the level and changes the apparent bearing.
- Receiver saturation, which masks the maximum.
How to close in on the source
Close to the source, it is advisable to switch to a smaller antenna or a near-field probe. Before intervening on any equipment or installation, the corresponding authorizations must be obtained.