How an environmental test profile is defined for a product

The starting point is the real environment the product will see during its life. The most severe or damaging events are translated into test conditions, and levels, ramps and duration are justified with the standard, the customer requirement or measured data.

The starting point is the life of the product

A useful profile begins by asking what the product will be exposed to from the time it is manufactured until it is retired: transport, storage, installation, operation and maintenance. Each phase has its own environment, and the most damaging one is not always operation.

Steps of the method

  1. Describe the life cycle and the conditions in each phase, with measured data where available.
  2. Identify the likely failure mechanisms: thermal fatigue of solder joints, corrosion, moisture absorption, loosening from vibration, among others.
  3. Choose the stresses that activate those mechanisms: temperature, humidity, cycling, vibration, shock, dust or water.
  4. Set levels, ramps and dwells based on the requirement source and the chamber capability.
  5. Define the sample state and when and how its operation is checked.
  6. Establish clear acceptance criteria before starting.
  7. Validate the profile with an instrumented sample and confirm that it is met at the sample, not just in the chamber.

Requirement sources

These can be test standards, industry standards, customer specifications or measurements of the real environment. When a standard is adopted, the current edition must be used and the test aligned with it; when a custom profile is designed, the justification must be documented.

What the engineer sees

The typical mistake is to copy a profile from another product with a different mass, use or failure mechanism. Another is to combine stresses in such a way that they mask one another, or to apply stresses so high that they cause failures that would never appear in service.

How to tell whether the profile is reasonable

If the profile activates the same failure mechanisms as the field and the sample reaches the intended levels, the test is representative. If not, the results say little about the real product, even if the procedure is followed.