Operating principle
A waveguide that is open at the end radiates, but with a severe mismatch and a poorly controlled pattern. Gradually flaring the cross section to form a horn progressively transforms the impedance of the guide toward that of free space. This reduces reflection and concentrates the radiation on the axis. The larger the aperture relative to the wavelength, the narrower the beam and the higher the directivity.
Why it is used as a reference
The geometry of a horn is simple and its behavior can be calculated from its dimensions. This means its gain can be estimated with good accuracy without relying on another antenna, and it is then confirmed by calibration. That is why it is used as a gain standard in the comparison or substitution method: the signal is measured with the horn and then with the antenna under test, and the difference gives the gain of the latter.
What the engineer sees in practice
- The pattern has a clean main lobe with relatively low side lobes, and the impedance is stable across the waveguide band.
- Its bandwidth is limited by that of the waveguide, so each horn covers a defined frequency range.
- Polarization is linear and is set by the orientation of the guide.
Types
Depending on the shape of the flare, there are sectoral, pyramidal and conical horns. The pyramidal horn flares in both planes and is the most common as a reference. Designs with ridges in the guide extend the bandwidth at the cost of a less direct calculation.
Limitations
- It is not suitable for low frequencies, where the guide and the aperture would be very large.
- The gain calculation assumes the far field and a well-built horn; manufacturing defects or dents alter it.
- Precise measurements include mismatch and a distance correction.