The general rule
A measurement method works well when the dimensions of the sample and the fixture are small compared with the wavelength, or when they are explicitly modeled as a wave structure. As frequency rises, the wavelength shortens and lumped-circuit models stop being valid, which is why the technique changes.
Low frequency: lumped circuit
A parallel-plate cell and an impedance meter give the capacitance and conductance of the sample, and from these the permittivity and losses. This is simple and very accurate for flat sheets, but at high frequencies cable inductances and fixture resonances appear and degrade the result.
Radio frequency and microwaves
- Open-ended coaxial probe: measures over a broad band with minimal preparation, useful for liquids and for soft solids or solids with a flat surface. Its accuracy is moderate and drops for very low-loss materials.
- Transmission line (coaxial or waveguide): the sample fills a section and scattering parameters are measured. It requires machining the part to a good fit, but it covers a broad band.
- Free space: there is no contact with the sample; antennas and lenses are used. It is suitable for high frequencies, elevated temperatures and large, flat parts.
- Resonant cavity: measures at one or a few frequencies, but with great sensitivity to low losses.
Decision criteria
- The frequency range that really matters for the application.
- Expected loss level: low losses favor resonators; high losses tolerate probes.
- Available sample shape and size, and whether it can be machined.
- Whether the test must be non-destructive or at controlled temperature.
- Required accuracy, and whether a comparative measurement is enough.
What the engineer sees
When comparing two methods on the same material, it is normal to see small differences, attributable to sample preparation, the analysis model and the uncertainty inherent in each technique. A large discrepancy usually indicates air gaps, a non-homogeneous sample or a method outside its range of validity.