Charging is integrated with solar generation through a meter at the point of connection that reports the surplus, so that the charger modulates its current to consume the available photovoltaic energy and makes up any shortfall from the grid.

The mismatch to resolve

Photovoltaic generation peaks at midday, when the vehicle is usually away, or charging is needed at night. Integrating the two means matching consumption to production, or storing the energy until it is used.

How modulation works

A meter with current transformers at the service entrance measures the power being imported or exported. A controller compares that figure with the charger’s power and adjusts the current it offers the vehicle. In AC charging, this is done by changing the maximum current that the station communicates through the pilot signal; the vehicle takes that value as a limit. If there is a surplus, the current goes up; if the house consumes more, it comes down so as not to import from the grid.

Limits to be aware of

  • There is a minimum current below which the vehicle does not charge, so with low production the system must decide whether to top up from the grid or stop.
  • Current changes are not instantaneous, and clouds cause oscillations that the controller must filter.
  • Some vehicles react slowly to limit changes.
  • In single-phase to three-phase AC, switching between phases has equipment implications and is not always available.

With storage

A stationary battery absorbs the morning surplus and releases it when the vehicle connects. The energy flow is coordinated between the solar inverter, the battery, the house and the charger. With bidirectional charging, the vehicle itself can be the store.

What to verify

It is worth checking the correct location of the current sensors and their polarity, that the controller responds to loss of communication with a safe limit, and that the sum of generation, consumption and charging respects the limits of the inverter and the service entrance. In addition, the grid connection is subject to interconnection requirements. The installation must be done by qualified personnel in accordance with the applicable regulations.