EV-TEST 100 adapter rental for electric vehicle charging stations

Test adapter for mode 2 and mode 3 AC EVSE charging stations, with Type 2 IEC 62196-2 connector. It simulates an electric vehicle for installation, maintenance, commissioning and diagnostics.

EV-TEST 100 adapter for testing electric vehicle charging stations

The EV-TEST 100 adapter lets you run functional and electrical tests on EVSE chargers quickly and safely, without the need for a real electric vehicle.

It is designed for the installation, maintenance, commissioning and diagnostics of mode 2 and mode 3 AC charging stations. By simulating an electric vehicle, it makes it easy to validate the signals, protections and operating states defined in the IEC standards applicable to electric mobility infrastructure.

What the EV-TEST 100 is

It is a test adapter for EVSE charging stations with a Type 2 IEC 62196-2 connector. It simulates the connection of an electric vehicle to evaluate the charger before commissioning or during maintenance.

It simplifies field verification and reduces diagnostic times, because it gives direct access to the signals and communication states of the charging system.

Main functions

  • Compatible with mode 2 and mode 3 charging stations
  • Type 2 connector compliant with IEC 62196-2
  • Simulation of Control Pilot (CP) states
  • Current simulation via Proximity Pilot (PP)
  • Generation of fault conditions for functional testing
  • LED indicators for phase presence
  • Terminals for connecting measuring instruments
  • Verification of station power output
  • Protection by integrated fuse

What it lets you validate

  • Correct activation of the charging process
  • Communication signals between charger and vehicle
  • Status of the PE protective conductor
  • Response to simulated faults
  • Presence of voltage at the EVSE output
  • Recognition of cable current capacity

Technical specifications

Parameter Specification
EVSE compatibility Modes 2 and 3
Connector type Type 2 (IEC 62196-2)
CP states A, B, C, D
PP states NC, 13A, 30A, 32A, 63A
PE fault simulation Yes
FAULT E simulation Yes
Maximum voltage 415V AC
Frequency 50 / 60Hz
Maximum external load 240V / 10A
CP signal PWM 12V
Protection FF 10A fuse
Operating temperature 0°C to 40°C

Common applications

  • EV charger installation
  • Charging station commissioning
  • EVSE fault diagnostics
  • Preventive maintenance
  • Validation of electric mobility infrastructure
  • Integration of commercial chargers
  • Electrical laboratories and technical testing

Benefits of renting the EV-TEST 100

Immediate availability for projects

Ideal for temporary jobs, commissioning or one-off validations without buying the equipment.

Shorter test times

Direct electric vehicle simulation speeds up diagnostics and functional checks.

Lower investment in specialized instrumentation

You get access to the EVSE validation equipment only for as long as you need it.

International standards

Suitable for tests related to IEC 61851 and EV charging systems.

Support for technicians and integrators

Useful for maintenance companies, electrical contractors and EV infrastructure integrators.

Related standards

  • IEC/EN60364-7-722
  • IEC/EN61010-1
  • IEC/EN61851-1

Rental service

We rent EVSE adapters for testing electric vehicle charging stations in projects involving:

  • Installation
  • Maintenance
  • Technical validation
  • Diagnostics
  • Commissioning
  • Inspection and compliance

Ask about availability, rental periods and technical support options for testing EV charging infrastructure.