The mechanism
All of the charging current passes through a few contact surfaces. The power dissipated is P = I² × R, so a contact resistance that looks small produces heat concentrated in a very small volume, and that heat grows with the square of the current. That is why a connector that works well at low current can get very hot at full load.
What raises contact resistance
- Wear and loss of pressure: contact springs lose force with insertions and with heat, and the effective bearing surface shrinks.
- Dirt and oxidation: films on the metal, dust, salts or damaged platings.
- Incomplete or misaligned insertion: partial contact, or contact along a single edge.
- Loose terminals: the most frequent spot is usually the crimp or screw where the cable joins the contact, not the visible interface.
- Inadequate cable: a damaged conductor or one with a small cross-section heats the connector end by conduction.
- Environment: direct sun, high ambient temperature or poor ventilation reduce the margin.
A vicious circle
Heat oxidizes the metal and weakens the spring, which raises resistance, which generates more heat. That is why mild heating that is ignored can end in deformed plastic, melted contacts or damage to the vehicle.
What the equipment does and what is measured
Many connectors include temperature sensors at the contacts, and the charger reduces the current or stops the session when a threshold is reached. With the system de-energized, contact resistance can be measured with a four-wire micro-ohmmeter. Under load, infrared thermography locates the hot spot, and the millivolt voltage drop across the contact confirms the problem.
What to check first
First inspect visually for discoloration, deformed plastic and signs of arcing. Then compare the temperature between contacts of the same connector: a large difference points to the defective contact. Checking energized connectors or making replacements is a job for qualified personnel, in accordance with the applicable electrical regulations.