What problem it solves
Testing a charger with a real vehicle is slow, depends on the condition of the battery, and does not allow conditions to be repeated or dangerous faults to be induced. The simulator replaces the vehicle and presents the station with a vehicle’s electrical and communication behavior, in a controlled way.
What it emulates
- Control pilot signal: in AC conductive charging, the station and the vehicle communicate through a signal on a dedicated conductor. The vehicle states are signaled with voltage levels: A (not connected), B (connected, not ready), C (charging), D (charging with ventilation required), E (error) and F (station not available). The simulator selects the state and reads the pilot duty cycle, which reports the maximum current offered by the station.
- Proximity signal: a resistor in the connector reports the capacity of the cable.
- Digital communication: in DC stations and advanced systems, the exchange of messages about charging parameters.
- Battery demand: for DC, the voltage and current requested by the vehicle, with a load or an emulator that absorbs the energy.
What is tested with it
Checks cover the session start and end sequence, the response to state changes, the behavior of the station on loss of ground, a short circuit on the pilot or a diode failure, and the reaction to a current request above what is permitted. The accuracy of the delivered current and of the station’s energy metering is also measured.
How to interpret the result
A simulator test demonstrates that the station follows the protocol, not that it is compatible with every vehicle model. It is a reproducible baseline, complemented by interoperability testing with real vehicles. Connections to energized stations are made by qualified personnel.