How is battery capacity estimated with a controlled discharge?

Capacity is estimated by discharging the fully charged battery at constant current down to its cutoff voltage and integrating the current over time; the result in ampere-hours depends on the test current and temperature.

What is really being measured

Capacity is the electric charge the battery delivers between a fully charged state and a lower voltage limit. It is obtained by integrating the discharge current over the time taken to reach that limit: Q = ∫ I dt. If the product of voltage and current is also integrated, the result is the energy in watt-hours, which is the quantity most closely related to range.

How the test is done

  1. The battery is brought to full charge using the charging procedure defined by the manufacturer and left to rest so that the voltage stabilizes.
  2. The temperature is stabilized at the test value, because usable capacity changes with it.
  3. The battery is discharged with an electronic load in constant-current mode, logging voltage, current and temperature at a short sampling interval.
  4. The discharge ends on reaching the cutoff voltage, not before or after.
  5. The accumulated charge is calculated and compared with the rated value.

Why the result changes

Capacity is not a constant of the cell. At high currents, the internal voltage drop causes the cutoff limit to be reached sooner, so less charge is measured. At low temperature, internal resistance increases and the same thing happens. For this reason, a result only makes sense if the discharge rate (C-rate), temperature and cutoff voltage are stated.

What the engineer sees in practice

The curve of voltage versus delivered charge has a plateau and a steep final drop. If the drop comes too early, there is capacity loss or, in a pack, imbalance between cells: the weakest cell sets the end of the discharge. In packs with a battery management system, it is advisable to also log the individual cell voltages to find out which one limited the test.

Common mistakes

  • Comparing capacities measured at different rates or temperatures.
  • Using a current instrument with poor accuracy, when its error is integrated directly into the result.
  • Starting the test without a prior rest, with the battery still polarized.
  • Taking a single discharge as definitive: the first ones may differ from those of an already conditioned battery.

The ratio of measured to rated capacity is an indicator of state of health, but it does not replace an internal resistance measurement. Tests on traction batteries involve high energy and must be carried out by qualified people with the protective measures of the test bench.