What is the communication mode between vehicle and charger?

The communication mode between vehicle and charger defines how they coordinate to charge safely. In the usual AC mode, the control pilot signal tells the vehicle the maximum available current and the connection status; for DC, digital communication is added.

Why it is needed

Before delivering energy, the station must know that a vehicle is properly connected, that the ground is continuous and that the vehicle is ready. In turn, the vehicle needs to know how much current it can draw without overloading the cable or the installation. This coordination prevents energizing an exposed connector and prevents overloads.

The charging modes

  • Mode 1: connection to a standard outlet, with no communication or vehicle-specific protection.
  • Mode 2: connection to an outlet through a cable with an in-cable control box that adds protection and a pilot signal.
  • Mode 3: dedicated station with a control function and a permanent pilot signal.
  • Mode 4: DC charging station with an external converter and digital communication with the vehicle.

The pilot signal

In the modes with control, the station generates a signal on a pilot conductor. The vehicle responds by varying a resistance, and the station distinguishes states such as disconnected, connected, ready to charge or ventilation required. The station communicates the maximum current it offers through a characteristic of the signal, its duty cycle, and the vehicle limits its draw to that value. A proximity contact also indicates the capacity of the cable.

Digital communication

In DC charging and for advanced functions, the station and the vehicle exchange digital messages about the required voltage and current, the battery status and authentication. This allows the power to be adjusted during charging as directed by the BMS.

What an engineer sees in practice

If a vehicle does not start charging, the cause usually lies in this coordination: an unrecognized connection state, a poor ground, a cable with an inconsistent capacity indication or a communication failure. Vehicle simulators make it possible to reproduce each state to test a station. The exact names of the states and signals depend on the applicable standard.