How is the cell temperature of a module measured?

The cell temperature of a module is not measured directly: it is obtained with a sensor attached to the back of the module and then corrected, or it is calculated from the open-circuit voltage and the temperature coefficient.

Why it matters

The power and voltage of a module depend on the temperature of the cells, not of the air. To compare a measurement with the datasheet, that temperature must be known, and it can differ greatly from ambient, depending on irradiance, wind and mounting ventilation.

Method 1: back-side sensor

A temperature sensor, such as a thermocouple or a resistance sensor, is attached to the back of the module, behind a central cell, with good thermal contact and protected from direct sun and wind by insulation. The temperature at the back is very close to that of the cell at steady state, with a small difference due to the thickness of the layers. This is the method most used in the field.

Method 2: open-circuit voltage

Because open-circuit voltage depends on temperature according to a known coefficient, cell temperature can be estimated by comparing the measured voltage with the voltage the module would have at the reference temperature. It has the advantage of averaging the temperature of all the cells in the module, but it depends on knowing the coefficient and the voltage at reference well, and irradiance also influences the voltage.

Method 3: thermography

A thermal camera gives an image of the temperature distribution, useful for detecting hot spots, not for obtaining a reliable absolute value. It sees the surface of the glass or the backsheet, whose emissivity and reflections affect the reading.

Sources of error

  • Poor thermal contact of the sensor, or sensor exposed to sun or wind.
  • Measuring in non-steady conditions, just after a change in irradiance: the module takes time to reach equilibrium.
  • Choosing an unrepresentative cell, such as an edge cell or one near a hot spot.
  • Using air temperature as a substitute.

How to interpret the result

With cell temperature and irradiance, I-V curves are corrected and performance is evaluated against what is expected. It is advisable to record the method. Measurements on illuminated modules involve live voltage and must be carried out by qualified personnel, in accordance with the applicable safety regulations.