What is mismatch between modules?

Mismatch between modules occurs when interconnected modules have different I-V curves and the whole yields less than the sum of its parts, because the lowest current governs in series and the lowest voltage governs in parallel.

Short answer

Mismatch is the power loss that occurs when modules or cells whose electrical characteristics are not identical are connected together. The power of the assembly ends up lower than the sum of the power each element would deliver separately.

Why it happens

Two elements connected in series must carry the same current. If one can deliver less current, because it is shaded, soiled or degraded, it limits all the others, which cannot deliver all of theirs. In parallel the problem is the opposite: the elements must share the same voltage, and one with a lower voltage drags the rest to an operating point that is not optimal for any of them.

Common causes

  • Manufacturing spread: modules from the same family with small differences.
  • Uneven shading and soiling.
  • Different degradation over time, from microcracks, hot spots or uneven aging.
  • Different orientations or tilts within the same string.
  • Mixing modules of different models or ages in an expansion.
  • Temperature differences between modules.

What an engineer sees in practice

A string producing less than the average of its modules would suggest, an I-V curve with steps, and modules with abnormal temperatures on a thermal camera. Bypass diodes let current avoid a badly affected section, but at the cost of losing that section’s voltage.

How it is reduced

Group modules with similar characteristics, design strings with the same orientation and exposure, separate inverter inputs for different arrays, and clean and inspect by zone. Optimizers and microinverters decouple individual modules, at the cost of more complexity.

An example

If a single module in a string is partially shaded, the current of the whole string drops, far more than in proportion to the shaded area. Electrical work on a solar array must be carried out by qualified personnel in accordance with current regulations.