How does a photovoltaic cell work?

A photovoltaic cell converts light into electricity through a semiconductor p-n junction: photons generate electron-hole pairs and the junction's internal field separates them, producing a direct current when the circuit is closed.

The principle

A solar cell is essentially a semiconductor diode, normally made of silicon, designed so that light reaches the junction. When a photon with enough energy is absorbed, an electron moves from the valence band to the conduction band and leaves a hole behind. That electron-hole pair is the charge carrier that makes electricity possible.

Why current is generated

The junction between the n-type material, with an excess of electrons, and the p-type material, with an excess of holes, creates an internal electric field. That field pushes the electrons to one side and the holes to the other. Without it, the pairs would recombine and the energy would be lost as heat. With this separation, the cell accumulates charges at its metal contacts, and when a load is connected, direct current flows.

What determines current and voltage

  • Current: to a good approximation, it is proportional to the irradiance the cell absorbs and to its area. More light means more photons and more pairs generated.
  • Voltage: it depends on the material and the characteristics of the diode; it varies little with irradiance but drops as temperature rises.
  • Power: the product of the two, which depends on the operating point imposed by the load.

Why not all the light is used

Photons with energy below the semiconductor’s bandgap are not usefully absorbed. Those with higher energy give up the excess as heat. Added to this are surface reflection, shading by the metal contacts, carrier recombination and internal electrical resistance. That is why the practical efficiency of a cell falls far short of the incident solar energy.

What an engineer sees in practice

An individual cell delivers a small voltage, so many are connected in series to form a module. Current changes with light and voltage falls with heat, which explains why a module yields less on a hot day even with the same sun. Its behavior is described by the I-V curve.

An example

With a partially covered cell, the current drops in proportion to the illuminated area, although the voltage hardly changes. In a series string, that cell limits the current of all the others, and this is where bypass diodes and the subject of shading come from. Electrical work in solar fields, where voltage is present as long as there is light, must be done by qualified personnel in accordance with current regulations.

We do real tests, on video! Watch them on our YouTube channel →