Why it differs from an industrial machine
A wind turbine operates with variable speed and load dictated by the wind, often in remote, hard-to-reach locations. Routes with a portable data collector are impractical, so monitoring is usually continuous, with installed sensors and remote analysis.
Which components are monitored
- The main rotor bearing, which turns slowly and generates weak signals.
- The gearbox, with gears and bearings running at various speeds.
- The generator and its bearings.
- The tower and the nacelle, in terms of their structural response.
How the measurement is adapted
- Fault frequencies depend on rotational speed, so spectra are normalized by speed (order analysis) or grouped by operating ranges.
- Power, speed and other process parameters are recorded along with the vibration, so that only equivalent conditions are compared.
- For low-speed components, sensors and techniques with good low-frequency response are used.
What faults are looked for
Bearing defects, wear or pitting in gears, unbalance or misalignment of the rotor, and problems in the generator. The data are compared with trends and with band alarms.
How to interpret the result
Without normalizing for speed and load, a change in the wind can look like a fault. That is why a reliable diagnosis is based on the trend under comparable conditions and is confirmed with other techniques, such as oil analysis.
Work at height and on equipment with stored electrical or mechanical energy must be carried out by qualified personnel and in accordance with the applicable regulations and safety procedures.