What is expected of a base
The base must support the machine without deforming, maintain alignment and not amplify vibration. A weak base acts like a spring: with insufficient stiffness, part of the rotor force is converted into movement of the structure, and if a natural frequency coincides with running speed, resonance appears.
What is checked
- Anchors and bolts: tightness, condition and absence of corrosion.
- Grout and contact: voids or cracks between the baseplate and the concrete.
- Soft foot: one of the machine’s feet does not sit flat and distorts the frame when tightened.
- Welds and structure: cracks and deformation in metal bases.
- Piping and connections: stresses transmitted to the machine.
Soft foot check
With a dial indicator at each foot, loosen the bolts one at a time and observe how much the foot lifts. If the variation is appreciable, the machine was distorted, and this is corrected with shims or by machining the support.
Vibration measurements
- Measure on the machine and on the base, at the same points and in the same directions.
- A marked jump in amplitude between the foot and the base indicates looseness or poor contact.
- A phase difference between the two points also signals a loose support.
- An impact test or a startup and shutdown make it possible to locate natural frequencies.
How to interpret the result
On a sound base, the machine and the foundation move in phase and with amplitudes of the same order. If vibration worsens at a specific speed, suspect resonance and evaluate stiffening the base or changing the mass.