How is a gear reducer evaluated?

A gear reducer is evaluated by combining vibration analysis, oil review, temperature and inspection, because gearing leaves its main signature at the gear mesh frequency and its sidebands, which are read in the spectrum.

The characteristic signal

Each gear pair produces vibration at its gear mesh frequency, which is the number of teeth on a gear multiplied by its rotational speed. In a healthy reducer that frequency and its harmonics are present, because contact between teeth always generates some varying force, but they remain stable over time.

What the spectrum indicates

  • Increase in gear mesh frequency: may be associated with wear, higher load or misalignment between shafts.
  • Sidebands: spaced at the rotational speed of the gear that modulates them, they point to eccentricity, a damaged tooth or a form error on that gear.
  • Excited natural frequencies: may appear when there is rattling or excessive backlash.

Other complementary techniques

  • Oil analysis: metal particles and their size show wear in progress.
  • Temperature: a sustained increase suggests friction or poor lubrication.
  • Inspection: contact patterns, pitting and wear on the tooth flanks.
  • Noise: changes in sound point to contact problems.

How to measure

Measure close to the bearings of each shaft, with comparable load and speed between measurements, because the gear mesh frequency and the amplitudes depend on load. Sufficient spectral resolution is needed to separate the sidebands.

How to interpret the result

Always compare with a previous reference from the same reducer. An increase in sidebands over time is more significant than an isolated level. The diagnosis is confirmed with a second technique, such as oil analysis, before deciding on an intervention.

When it does not apply

If the reducer operates with highly variable load and speed, spot measurements may not be comparable. In those cases, always record the operating condition or use techniques synchronized with rotation, such as synchronous signal averaging.