What causes cavitation vibration in pumps?

Cavitation in a pump produces vibration because the liquid vaporizes in low-pressure zones and the bubbles collapse violently on reaching higher-pressure zones, generating impacts that excite the pump with broadband noise.

What happens inside the pump

When the local pressure at the impeller inlet falls below the vapor pressure of the liquid, vapor bubbles form. As they move into a higher-pressure zone, those bubbles collapse abruptly. Each collapse produces a localized impact that generates noise, vibration and, over time, pitting in the material.

Why it happens

The pump requires a certain available suction pressure above the vapor pressure, expressed as NPSH. Cavitation occurs when the NPSH available from the installation is insufficient compared with the NPSH required by the pump. Typical causes are:

  • Low level in the suction tank or excessive suction lift.
  • Long suction piping, with restrictions, dirty strainers or partially closed valves.
  • Liquid at a higher temperature than expected, which raises the vapor pressure.
  • Operation very far from the best efficiency point.

What the engineer sees

  • A sound similar to gravel moving through the pump.
  • In the spectrum, an increase in broadband energy, often at high frequency, along with a raised noise floor.
  • Pressure and flow fluctuations, and a drop in performance.
  • Over time, erosion of the impeller vanes.

How it is corrected

  1. Increase the NPSH available: raise the level, reduce suction losses or cool the liquid.
  2. Operate within the range recommended by the manufacturer.
  3. Verify that the suction valve is fully open and that the strainers are clean.

Other causes with similar symptoms, such as air entering the suction, should be ruled out before modifying the installation.