A two-channel FFT analyzer measures two signals simultaneously and calculates, in addition to the spectrum of each one, the relationships between them: relative phase, transfer function and coherence, which makes it possible to study how a system responds to an excitation.

What the second channel adds

With a single channel you obtain the spectrum of one signal. With two synchronized channels you can compare one signal with another in the frequency domain. The main quantities are the relative phase between channels, the transfer function (output over input) and the coherence, which indicates how much of the response is actually due to the input.

How it is used

  • Phase between two points: to distinguish misalignment, static or couple unbalance, or the motion of a base.
  • Impact tests: a hammer with a force sensor on one channel and an accelerometer on the other make it possible to obtain the natural frequencies and mode shapes of a structure.
  • Transmission between points: compares the vibration before and after an isolator or a joint.

How to read coherence

Its value varies between zero and one at each frequency. A value close to one means that the output is linearly related to the input. A low value indicates noise, nonlinearities, other excitation sources or a poorly made measurement, and the transfer function at those frequencies is not reliable.

Concepts that must be configured

  • Frequency range and resolution, which determine the acquisition time.
  • Window: different ones are used for transient and continuous signals.
  • Averaging, to reduce random noise.
  • Input coupling and range, to avoid saturation.

When it is not enough

If you only need to monitor a machine’s overall level on a route, a data collector or a vibration meter is sufficient. The two-channel analyzer adds value when you need to study the response of a system or the relationship between two points.