What is a moving-coil velocity sensor?

A moving-coil velocity sensor is an electromagnetic transducer in which a coil moves within a magnetic field and, by induction, generates a voltage proportional to the vibration velocity, with no need for an external power supply.

How it works

Inside the sensor there is a magnet and a coil; one of the two is elastically suspended while the other is fixed to the housing. When the housing vibrates, the suspended element tends to stay still because of inertia, and the relative motion cuts the field lines. According to Faraday’s law of induction, the induced voltage is proportional to the relative velocity, which is why the sensor measures velocity directly.

Practical characteristics

  • It is an active sensor: it does not need a power supply; its output can go directly to an instrument.
  • Limited frequency response: below its natural frequency the sensitivity drops, and toward high frequencies there are resonances.
  • It has moving parts: they can wear or go out of adjustment with shocks and over time.
  • It is sensitive to orientation: some models work only in the position indicated by the manufacturer, because of gravity acting on the suspended mass.

Where it has been used

Historically it was the usual transducer for measuring machinery casing vibration, because velocity correlates well with overall severity. Today many systems use accelerometers with integration, although moving-coil sensors remain in existing installations.

What the engineer sees

A loss of sensitivity over time, readings that depend on the mounting position or an intermittent signal are typical symptoms of wear in the suspension or the cable. It is verified with a vibration calibrator or against another known sensor.

When it does not apply

It is not suitable for high frequencies, such as incipient bearing defects, or for very slow movements.

What to check first

Before attributing a change in reading to the machine, confirm the mounting orientation, the condition of the cable and the sensor’s response against a reference sensor. If the sensor is old, it is reasonable to assume that its sensitivity is no longer the original value.