What is measured and with what
The probe generates a high-frequency field and detects how the conductive material of the shaft modifies it. The smaller the distance, the greater the effect, and the system converts this into a voltage proportional to the gap within its linear range. That signal yields two types of information: position (average level) and motion (variable component).
Radial and axial
- Radial: measures the motion of the shaft within the bearing and the position where it settles.
- Axial: measures displacement along the shaft, the movement of the thrust collar or the position of the rotor relative to the casing.
General procedure
- Mount the probe on its rigid bracket, perpendicular to the surface.
- Set the initial gap at the center of the linear range, using the voltage reading.
- Connect the cable and signal conditioner that correspond to that probe and its length.
- Record the DC value and the dynamic signal with an analyzer or a monitoring system.
Sources of error
- Shaft material and finish: sensitivity changes with the alloy and the surface. It must be calibrated with the actual material.
- Runout: marks, dents or magnetization generate a signal that is not real motion.
- Flexible bracket: the probe vibrates with the bracket and measures motion that does not exist.
- Temperature: it affects the sensor and the cable.
How to interpret the result
A slow change in the average position usually indicates wear, a load variation or a temperature change. An increase in dynamic amplitude indicates a change in rotor behavior that must be analyzed with spectrum and phase.