Relative shaft vibration is measured with proximity sensors that do not touch the shaft and that record its motion relative to the casing or bearing on which they are mounted, something an accelerometer on the casing does not see as clearly.

What relative means

The sensor measures the distance between its tip and the shaft surface. Because the sensor is fixed to the support, what it records is the motion of the shaft relative to that support. In machines with oil-film bearings and heavy casings, the shaft moves within the bearing clearance and much of that motion is not transmitted to the casing, which is why it is measured directly at the shaft.

How it is installed

  • Two probes per measurement plane, 90 degrees apart, to reconstruct the shaft orbit.
  • Mounted as close as possible to the bearing.
  • A phase sensor (a mark on the shaft) to reference the angle and obtain the vibration phase.

What is obtained

The signal has two parts. The DC component gives the average position of the shaft within the clearance, which is useful for seeing how it settles in the bearing. The AC component is the vibration proper, which is plotted as waveform, spectrum and orbit.

What the engineer sees

A nearly circular, stable orbit is normal in healthy rotors. A very elliptical orbit can indicate different support stiffness in each direction; shapes with internal loops are associated with non-synchronous frequency components, and the precession (with or against the rotation) helps to classify the cause.

Errors that degrade the measurement

  • Runout: shaft defects such as scratches, residual magnetism or conductivity variations are read as false vibration. The reading is checked at slow speed.
  • Calibration: sensitivity depends on the shaft material; the correct one must be used.
  • Mounting: a probe on a flexible bracket measures its own motion.

Installation and commissioning on energized or operating machines must be carried out by qualified personnel, following the applicable safety procedures.