How is a vibration monitoring route set up?

You define which machines to measure, at which points and in which directions, with which parameters and how often, so that each round repeats the same measurements under the same conditions and the data are comparable over time.

What the goal is

A route is an ordered sequence of points that are measured periodically with a data collector. Its value lies in the trend: what matters is how a point changes over time, not an isolated measurement. For the trend to be valid, the measurement must be taken the same way every time.

Steps to build it

  1. Select the machines: prioritize by criticality, consequence of failure, cost and ease of replacement.
  2. Define the points: normally each bearing support, near the load zone, in radial directions (horizontal and vertical) and axial where appropriate.
  3. Mark the points physically: with a mark or a fixed mounting base, so that the position can be repeated.
  4. Choose parameters and ranges: overall value in the appropriate quantity, a spectrum with a maximum frequency that covers the expected phenomena and sufficient resolution, and waveform when needed.
  5. Record the machine data: speed, number of poles, gear teeth and bearing geometry, in order to identify frequencies.
  6. Establish the baseline: measurements with the machine in good condition, which serve for comparison.
  7. Set the frequency: shorter intervals for critical machines or those with fast-developing faults, longer for those with slow-developing ones.
  8. Organize the route: by efficient physical walk-through and by hierarchy in the software.

Repeatability conditions

  • Measure with the machine under similar operating conditions, noting load and speed.
  • Use the same type of sensor and mounting, because the mounting mainly affects high frequencies.
  • Keep the orientation and direction of each point.

How to maintain it

A route is not final. It is reviewed after repairs, process changes and detected faults: the points, the frequency and the alarm levels are adjusted. Measurements next to rotating parts must be taken in compliance with the plant’s safety procedures.