What is mechanical looseness?

It is excessive play between parts that should be firmly joined, such as a bearing in its housing, a machine on its base or a component on its shaft, and it shows up as vibration with many harmonics and unstable phase.

What it is and why it vibrates

A rigid joint transmits forces linearly: a periodic force is followed by a response at the same frequency. With looseness, the part lifts off, strikes and reseats on each cycle. Stiffness changes with position, so the system is no longer linear. A nonlinear response generates components at multiples of the excitation frequency, which is why the spectrum fills with harmonics.

Types

  • Structural: loose base, bedplate or anchor bolts, cracks or soft foot. The machine is not properly secured to its support.
  • Rotating: excessive play in a journal bearing, in the fit of a rolling bearing on its shaft or of a rotating component on the shaft.

What is seen in the measurements

  • A series of harmonics of 1X, sometimes many, with varying amplitudes.
  • In more advanced cases, fractional components, such as halves of the rotating speed, which add to the comb of harmonics.
  • A time signal that is clipped or irregular in shape, with impacts.
  • Unstable or erratic phase that changes from one measurement to the next.
  • Directional behavior: sometimes greater in the vertical direction or in the direction of the play.

How to distinguish it

Unbalance and misalignment show few harmonics and stable phase. Looseness tends to do the opposite. Comparing measurement points also helps: in structural looseness, the reading on the machine foot and on the base differ markedly, since there is relative movement between the two.

What to check first

  1. Anchor bolts and base tightening.
  2. Soft foot and shims.
  3. Cracks in the bedplate or foundation.
  4. Fit of the bearings in their housing and on the shaft.
  5. Fasteners on covers, supports and mounted components.

Retightening anchors or working on equipment requires stopping the machine and isolating its energy sources using the applicable lockout procedures.