What is rotor unbalance?

It is an uneven distribution of mass around the axis of rotation, so that the center of mass does not coincide with the axis and the rotation generates a centrifugal force that produces vibration at the rotating frequency.

The physical origin

A perfectly balanced rotor has its inertia axis on the axis of rotation. If one part has more mass on one side, an eccentric mass appears. As it rotates, that mass generates a centrifugal force proportional to the mass, to its eccentricity and to the square of the angular velocity. The force rotates with the rotor, so a periodic force acts on the supports once per revolution.

Typical causes

  • Buildup of dirt or product on blades, impellers or fans.
  • Uneven wear or erosion.
  • Loss of a part, a counterweight or a bolt.
  • Imperfect manufacturing or assembly.
  • A bent shaft or thermal distortion.

Types

  • Static: the center of mass is offset from the axis, and the two supports vibrate in phase.
  • Couple: there are two unbalanced masses at 180° in different planes; the center of mass may lie on the axis, but the vibrations at the two ends are out of phase.
  • Dynamic: a combination of both, and the most common in practice.

How it appears in measurements

  • A dominant peak in the spectrum at 1X, that is, at the rotating frequency, with small amplitudes at the harmonics.
  • Mainly radial vibration.
  • Stable, repeatable phase; the horizontal and vertical readings on the same support differ by about a quarter of a turn.
  • Amplitude increases with speed, at least away from a resonance.

When it is not unbalance

A peak at 1X is not enough to conclude that there is unbalance. Misalignment, a resonance, a bent shaft or certain looseness problems can also raise it. Phase, direction and behavior with speed help to distinguish them. If the 1X vibration is high but the phase is unstable or the axial vibration is dominant, look for another cause before balancing.