The physical cause
The radiation reaching the camera from a surface is the sum of what the material emits and what it reflects. The lower the emissivity, the greater the reflected fraction. A shiny metal bar emits little and acts almost like an infrared mirror: it can show the outline of a person, a lamp, a hot motor, or the sun, and that image looks like the bar’s own heat.
How to recognize a reflection
- When the viewing angle changes, the “hot spot” moves or disappears, whereas real heat stays where it is.
- It has shapes that correspond to objects in the surroundings, or sharp edges on a smooth surface.
- It appears on shiny, curved surfaces, and not on areas with paint or tape of known emissivity.
- If a piece of cardboard or a screen is placed between the suspected source and the surface, the anomaly changes.
Common errors
- Interpreting a hot patch on a polished cover as an internal defect.
- Measuring perpendicular to a specular surface: it reflects the camera itself and the person operating it.
- Using a high emissivity on a shiny metal “to get a reasonable reading,” which hides the problem instead of correcting it.
How to reduce them
- Observe from two or more angles and compare.
- Measure on areas of higher emissivity, such as painted terminals or a small piece of tape of known emissivity.
- Determine the reflected apparent temperature and enter it into the camera.
- Shield nearby radiation sources or inspect at times with fewer sources.
- Confirm with another technique if the finding is important.
What this says about the method
A diagnosis based on a single image of a shiny surface deserves suspicion. A reflection is not a camera fault: it is a property of the surface that the thermographer must control.