What does the ASTM D149 dielectric breakdown standard cover?

ASTM D149 describes how to determine the breakdown voltage and dielectric strength of solid electrical insulating materials at power frequencies, by applying an increasing voltage to a sample until it fails.

General scope

The standard deals with the dielectric breakdown of solid insulators, such as films, sheets, resins and ceramics, subjected to AC voltage at power frequencies. It defines how to prepare and condition the samples, the electrodes, the surrounding medium, the ways of applying the voltage and how to report the result.

What is obtained

The primary result is the breakdown voltage, the value at which the material stops insulating. Dividing it by the thickness gives the dielectric strength, expressed as voltage per unit thickness. This division is a simplification: dielectric strength is not a material constant, and it depends on the thickness and the test geometry.

How it is done in general terms

  • The sample is placed between two electrodes of defined geometry, generally immersed in an insulating fluid, such as oil, to prevent surface discharges through the air.
  • The voltage is applied using one of several schemes: a continuous rise, or stepwise increases with a dwell at each level.
  • The test ends when the current exceeds a trip threshold or a visible puncture appears.
  • It is repeated on several samples, because breakdown has statistical scatter.

What influences the result

  • Thickness: thinner samples usually show higher strength per unit thickness.
  • The rate of voltage rise.
  • Temperature, humidity and prior conditioning.
  • The shape of the electrodes and the surrounding medium.
  • Internal defects, voids or impurities, which cause early failures.

What it does not represent

The value obtained in the rapid test is not the voltage the material withstands in continuous service: degradation from partial discharges, heat or aging makes the working voltage much lower. Nor is it an intrinsic property that can be carried over to another thickness or geometry without care.

Common errors

  • Comparing values from laboratories that used different electrodes or voltage schemes.
  • Reporting a single result instead of the distribution over several samples.
  • Ignoring surface or edge discharges that invalidate the breakdown.
  • Using the value as a design criterion without safety factors.

This guide only describes the scope; conditions, electrodes and criteria should be taken from the current edition. High-voltage tests must be carried out by qualified personnel in accordance with the applicable safety regulations.