What is the comparative tracking index?

The comparative tracking index (CTI) is the maximum voltage, obtained in a standardized test with a contaminating solution, at which the surface of an insulator holds out without forming conductive carbon paths.

What the CTI indicates

The CTI expresses in volts the resistance of an insulating material’s surface to the formation of conductive paths caused by the combination of an electric field and moist contamination. The higher the value, the better the material tolerates those conditions. It is a comparative index: it serves to rank materials under the same procedure, not to predict the exact life of a part in service.

Why tracking occurs

When a film of water with salts or dust covers an insulating surface and there is voltage between two points, a small leakage current flows. That current heats the film and dries it unevenly, forming dry bands where the voltage concentrates and tiny discharges appear. Each discharge degrades the material; in many organic polymers it leaves carbon, which is conductive. The carbon shortens the path and promotes new discharges until a track forms that can end in a surface short circuit.

How the value is obtained

The standardized procedure places two electrodes on the surface of the test specimen, applies a set voltage and lets drops of a defined electrolytic solution fall at regular intervals. This is repeated at different voltages. The result is the highest voltage at which the material withstands the specified number of drops without the leakage current tripping the failure criterion or sustained combustion occurring. The exact procedure, solution and criteria are in the IEC 60112 standard, and its current edition should be consulted.

How it is used in design

  • Materials are grouped into categories according to their CTI, and that category plays a part in determining minimum creepage distances in insulation coordination standards.
  • A high CTI allows, all else being equal, shorter creepage distances, which reduces the size of boards and connectors.
  • Materials with mineral fillers, or with a chemistry that leaves no carbon, tend to perform better than those that carbonize easily.

What the engineer sees in practice

On a datasheet, the CTI appears as a value in volts or as a category. It must be read with caution: it depends on the color, the flame-retardant additive and the lot, and the sheet usually gives the value for the natural material. If the application involves severe contamination, humidity or altitude, the CTI is only one of the criteria; the pollution degree of the environment and the geometry of the design also count.

When it is not enough

The CTI does not measure resistance to high-energy arcs or erosion from corona. Nor does it replace a test of the finished assembly when real contamination differs greatly from the laboratory solution.